1981
DOI: 10.1099/0022-1317-55-1-223
|View full text |Cite
|
Sign up to set email alerts
|

Rapid Detection of Human Viruses in Faeces by a Simple and Routine Immune Electron Microscopy Technique

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
21
0

Year Published

1988
1988
2018
2018

Publication Types

Select...
5
2
2

Relationship

1
8

Authors

Journals

citations
Cited by 40 publications
(21 citation statements)
references
References 16 publications
0
21
0
Order By: Relevance
“…As mentioned before, the results of the present study should be viewed with caution specially for the presence of GARV and TTV, with respect to: i) the initial volume used for the viral concentration, since there are studies that use more than 500 mL and viruses may have been diluted when discharged into water bodies; ii) the methodology used for the concentration of GARV, as there are studies (Berthiaume et al, 1981;Smith and Gerba, 1982) which show that the use of positively charged membranes are more efficient for GARV recovery from water samples and iii) the limited analytical sensibility of conventional PCR when compared to Real-Time PCR. Taking this into consideration, the low number of samples positive for GARV may have due to the adsorption-elution protocol used for viral concentration, as well as the volume used in this process.…”
Section: Microbiological Parametersmentioning
confidence: 94%
See 1 more Smart Citation
“…As mentioned before, the results of the present study should be viewed with caution specially for the presence of GARV and TTV, with respect to: i) the initial volume used for the viral concentration, since there are studies that use more than 500 mL and viruses may have been diluted when discharged into water bodies; ii) the methodology used for the concentration of GARV, as there are studies (Berthiaume et al, 1981;Smith and Gerba, 1982) which show that the use of positively charged membranes are more efficient for GARV recovery from water samples and iii) the limited analytical sensibility of conventional PCR when compared to Real-Time PCR. Taking this into consideration, the low number of samples positive for GARV may have due to the adsorption-elution protocol used for viral concentration, as well as the volume used in this process.…”
Section: Microbiological Parametersmentioning
confidence: 94%
“…The low rates for detection of GARV genomes may be associated to the methodology used for concentration of the samples, since other methods were used in the past for this purpose (Berthiaume et al, 1981;Smith and Gerba, 1982). Nevertheless, a number of recent reports described the use of adsorption-elution protocol for the detection of GARV in water and sewage samples (Li et al, 2011;Rigotto et al, 2010), although low percentages of rotavirus genomes were reported.…”
Section: Microbiological Parametersmentioning
confidence: 99%
“…In this technique, copper grids, previously prepared with collodion film and stabilized with carbon were first incubated with protein A (1ml/ml), placed in contact with a virus-specific antibody. After this, the grids were washed in PBS drops, incubated with the viral suspension washed with drops of water and negatively stained with 2% ammonium molybdate, pH 5.0 (Almeida & Waterson,1969;Derrick, 1973;Berthiaume et al, 1981).…”
Section: Negative Staining Technique (Rapid Preparation)mentioning
confidence: 99%
“…Several decades after the rotavirus description many studies have been carried out to compare detection techniques (11,(16)(17)(18)(19)(20)(21) . Currently, several commercial tests are available from less laborious based techniques that enable a quick diagnosis, e.g.…”
Section: Discussionmentioning
confidence: 99%