2022
DOI: 10.1055/s-0042-1757241
|View full text |Cite
|
Sign up to set email alerts
|

Rapid-Deployment Aortic Valve Replacement in a Real-World All-Comers Population

Abstract: Background This study was conducted to evaluate the mid-term outcomes of rapid-deployment aortic valve replacement (AVR) using Edwards Intuity. Methods A total of 215 patients underwent rapid-deployment AVR using Edwards Intuity at our institution. The median follow-up duration was 22 months (interquartile range, 8–36). Primary outcomes were overall survival, cumulative incidence of cardiac death, and major adverse cardiac events. Secondary outcomes were early and 1-year hemodynamic performances of t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 5 publications
(6 citation statements)
references
References 30 publications
(36 reference statements)
0
6
0
Order By: Relevance
“…In our institution, a single surgeon (K.H.K.) used Edwards Intuity exclusively for patients who planned to receive a bioprosthetic valve, regardless of the etiology of aortic valve disease [ 10 ]. The fact that BAVs were present in 52.6% of the entire cohort and that 11.2% of the study population had type 0 BAVs demonstrates that our series was indeed a real-world all-comers setting, because more than 50% of all AVRs for aortic stenosis are estimated to be due to BAVs according to a previous report [ 20 ].…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…In our institution, a single surgeon (K.H.K.) used Edwards Intuity exclusively for patients who planned to receive a bioprosthetic valve, regardless of the etiology of aortic valve disease [ 10 ]. The fact that BAVs were present in 52.6% of the entire cohort and that 11.2% of the study population had type 0 BAVs demonstrates that our series was indeed a real-world all-comers setting, because more than 50% of all AVRs for aortic stenosis are estimated to be due to BAVs according to a previous report [ 20 ].…”
Section: Discussionmentioning
confidence: 99%
“…By investing several extra minutes in additional anchoring sutures, we were able to achieve complete annulus fitting and substantially reduce the occurrence of PVL. We also believe that this complete annulus fitting contributed to the lower incidence of pacemaker implantation in our series (1.4% before discharge and 2.3% during follow-up) [ 10 ].…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Even in cases of aortic valves with elliptical opening, Intuity valve can be well-fixed and takes best advantage of our modified technique. Distorted geometry of native annulus was frequently observed, particularly in bicuspid aortic valves, and with additional anchoring sutures, the sewing ring of Intuity valve could be completely fitted to the native annulus ( 24 ). The skirt portion of Intuity valve also have advantages in reducing turbulent flow and optimizing the hemodynamic performance by reshaping the left ventricular outflow tract, particularly in patients with elliptical or distorted LVOT.…”
Section: Discussionmentioning
confidence: 99%