1999
DOI: 10.1039/a808426b
|View full text |Cite
|
Sign up to set email alerts
|

Rapid automated spectrophotometric competitive complexation studies of drugs with cyclodextrins using the flow injection gradient technique: tricyclic antidepressant drugs with α-cyclodextrin

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
7
0

Year Published

2000
2000
2020
2020

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(8 citation statements)
references
References 35 publications
(34 reference statements)
1
7
0
Order By: Relevance
“…The inclusion complexes of CDs with tricyclic drugs have received attention over the past decades (Ali et al, 2012;Aree, 2020;Cano et al, 2007;Castiglione et al, 2017;Cruz et al, 2008;De Sousa et al, 2008;Georgiou et al, 1999;Junquera et al, 2001;Kundu and Roy, 2017;Nishikawa and Kamimura, 2011;Rajendiran et al, 2014;Redenti et al, 2000;Valsami et al, 1992). However, non-homogeneous results are found in the literature.…”
Section: Introductionmentioning
confidence: 99%
“…The inclusion complexes of CDs with tricyclic drugs have received attention over the past decades (Ali et al, 2012;Aree, 2020;Cano et al, 2007;Castiglione et al, 2017;Cruz et al, 2008;De Sousa et al, 2008;Georgiou et al, 1999;Junquera et al, 2001;Kundu and Roy, 2017;Nishikawa and Kamimura, 2011;Rajendiran et al, 2014;Redenti et al, 2000;Valsami et al, 1992). However, non-homogeneous results are found in the literature.…”
Section: Introductionmentioning
confidence: 99%
“…Developments of FIA have been further stimulated by the additional advantages of automation, such as increased precision, decreased cost of individual assay, and the satisfactory reliability of automated equipment [29]. One of the important features of the flow injection method is the possibility of adapting the flow pattern to the requirements of a particular determination [30] and hence, continuous flow titration methods have been reported by many investigators [31][32][33][34][35][36][37][38][39][40].…”
Section: Introductionmentioning
confidence: 99%
“…A number of methods are available in the literature for the determination of PCT, such as high-performance liquid chromatography [8][9][10], Chemiluminescence [11], Fluorescence [12], pulse perturbation technique [13], Spectrofluorimetric [14], and several others. A very few methods are reported in the literature for the determination of PTP in pharmaceutical formulations which include high performance liquid chromatography [15][16][17], Liquid chromatography [18], and flow injection technique [19].…”
Section: Introductionmentioning
confidence: 99%