2019
DOI: 10.1002/ejlt.201800392
|View full text |Cite
|
Sign up to set email alerts
|

Rapid Assessment of Monovarietal Portuguese Extra Virgin Olive Oil's (EVOO's) Fatty Acids by Fourier‐Transform Near‐Infrared Spectroscopy (FT‐NIRS)

Abstract: A rapid method for the evaluation of fatty acids (FA) of monovarietal Portuguese extra virgin olive oils (EVOOs) (n = 82) from Alentejo, south‐central region of Portugal, is developed based on Fourier‐transform near‐infrared spectroscopy (FT‐NIRS). The contents of FA‐components (previously determined per conventional gas chromatography) are correlated with FT‐NIRS data (independent variable), by means of full cross‐validation partial least squares regression (CVPLSR). CVPLSR is run using standard normal variat… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
18
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 15 publications
(22 citation statements)
references
References 23 publications
1
18
0
Order By: Relevance
“…Five spectra were collected from each sample, and an average spectrum was used for further mathematical processing and chemometrics analysis. Spectra data were obtained in the entire near infrared region of 12,500-3600 cm −1 (800-2777 nm) after a total of 32 scans with a scanner velocity of 10 kHz and an average resolution of 16 cm −1 , with a receiver gain function with the lowest gain setting defined as 1 [23]. Each spectrum constituted 1137 points, which means that the first 20 values of each spectrum were discarded because large parts of the spectral noise could be found below 3741 cm −1 (2673 nm).…”
Section: Sample Spectra Acquisition and Processingmentioning
confidence: 99%
“…Five spectra were collected from each sample, and an average spectrum was used for further mathematical processing and chemometrics analysis. Spectra data were obtained in the entire near infrared region of 12,500-3600 cm −1 (800-2777 nm) after a total of 32 scans with a scanner velocity of 10 kHz and an average resolution of 16 cm −1 , with a receiver gain function with the lowest gain setting defined as 1 [23]. Each spectrum constituted 1137 points, which means that the first 20 values of each spectrum were discarded because large parts of the spectral noise could be found below 3741 cm −1 (2673 nm).…”
Section: Sample Spectra Acquisition and Processingmentioning
confidence: 99%
“…It is also interesting to notice that Gal olive oils are the ones with the best performance in the model based on 13 C NMR DEPT 45. Galega Vulgar olive oils have already proven to be different from other varieties, namely, through their volatile profile [ 3 ] and their fatty acid profile [ 6 ]. The authors show that by applying a linear discriminant analysis to the fatty acids of olive oils from Alentejo, Galega Vulgar olive oils are very well separated from other olive oil varieties.…”
Section: Resultsmentioning
confidence: 99%
“…Few studies related to olive oils produced in Portugal using the typical olive varieties are described in the literature, mainly based on the use of chromatographic and spectroscopic techniques and chemometric tools [ 1 , 2 , 3 , 4 , 5 , 6 ]. Peres and coworkers [ 1 ] used artificial neural networks to achieve a chemometric classification of olive cultivars from Cobrançosa, Cordovil, Madural, Negrinha de Freixo, Santulhana and Verdeal Transmontana from the Trás-os-Montes region (northeast of Portugal).…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…An average spectrum was collected from each sample and was used for further mathematical processing and chemometrics analysis. Spectra data were obtained in the entire near infrared region of 12,500-3600 cm −1 (800-2777 nm) after a total of 32 scans with a scanner velocity of 10 kHz and an average resolution of 16 cm −1 , with a receiver gain function with the lowest gain setting defined as 1 [15]. The first 70 values of each spectrum were discarded to eliminate the noise below 4065 cm −1 (2460 nm).…”
Section: Sample Spectra Acquisition and Processingmentioning
confidence: 99%