2017
DOI: 10.3168/jds.2016-11824
|View full text |Cite
|
Sign up to set email alerts
|

Rapid assessment of bovine colostrum quality: How reliable are transmission infrared spectroscopy and digital and optical refractometers?

Abstract: The objectives of this study were to evaluate the performance of the transmission infrared (IR) spectroscopic method and digital and optical Brix refractometers for measurement of colostral IgG concentration and assessment of colostrum quality of dairy cows. Colostrum samples (n = 258) were collected from Holstein cows on 30 commercial dairy farms in Nova Scotia and Newfoundland, Canada. Colostral IgG concentrations of 255 samples were measured by the reference radial immunodiffusion (RID) assay and IR spectro… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

7
46
1
5

Year Published

2017
2017
2023
2023

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 47 publications
(59 citation statements)
references
References 42 publications
(93 reference statements)
7
46
1
5
Order By: Relevance
“…In our study we showed that Brix values were highly correlated with colostral IgG analyzed by RID. This fi nding is similar to the results of other research groups [1,15,34,35], who also found a moderate to high correlation between % Brix and IgG measured by RID. Besides we found that there was a signifi cant, but somewhat lower, correlation between the results obtained with the Brix refractometer and the concentration of colostral whey IgG measured with APE.…”
Section: Discussionsupporting
confidence: 81%
“…In our study we showed that Brix values were highly correlated with colostral IgG analyzed by RID. This fi nding is similar to the results of other research groups [1,15,34,35], who also found a moderate to high correlation between % Brix and IgG measured by RID. Besides we found that there was a signifi cant, but somewhat lower, correlation between the results obtained with the Brix refractometer and the concentration of colostral whey IgG measured with APE.…”
Section: Discussionsupporting
confidence: 81%
“…For the IR spectroscopy, the cut‐point of 50 g/L provided strong specificity and moderate sensitivity values across the unheated and heat‐treated colostrum (Table ). The accuracy of the IR spectroscopy (91.7%) to differentiate between unheated poor and good quality colostrum was higher than that reported in previous studies . However, the accuracy of the IR instrument to correctly determine quality of heat‐treated colostrum was lower with more samples with poor IgG levels categorized as adequate.…”
Section: Discussionmentioning
confidence: 56%
“…The IR spectroscopy and digital and optical Brix refractometers had a high-to-moderate agreement with the reference RID assay for assessing the quality of unheated colostrum and colostrum heat-treated at 60°C, which is similar to a previously report by the authors for unheated colostrum. 37 However, when colostrum heat-treated at 63°C, there was a poor agreement between the 3 methods and RID assay ( Table 1).…”
Section: Assessment Of Heat-treated Colostrum Qualitymentioning
confidence: 99%
See 1 more Smart Citation
“…It remains speculative why there was only poor agreement between the 2 methods. According to Elsohaby et al (2017), variations in the correlation coefficients could be related to the different non-IgG components in colostrum. The measurement via Brix refractometry assesses IgG concentrations indirectly, through assessing total dissolved solids that affect the sucrose concentration.…”
mentioning
confidence: 99%