2021
DOI: 10.1039/d1an00850a
|View full text |Cite
|
Sign up to set email alerts
|

Rapid antibiotic susceptibility testing using resazurin bulk modified screen-printed electrochemical sensing platforms

Abstract: Urinary tract infections (UTIs) are one of the most common types of bacterial infection. UTIs can be associated with multidrug resistant bacteria and current methods of determining an effective antibiotic...

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
7
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 17 publications
(8 citation statements)
references
References 48 publications
1
7
0
Order By: Relevance
“…To evaluate the MWCNT structure of the electrode and to confirm its non-porous nature, scan rate studies were carried out where the log of the peak current was measured against the log of the scan rate. For a typical diffusion-controlled redox process at a working electrode, one would expect a gradient of close to theoretical 0.5 [58]. The results of this work demonstrated a gradient of 0.4 which is close to the theoretical value of 0.5, thus indicating an electron process which was diffusional and demonstrated a non-porous electrode structure [59].…”
Section: Electrochemical Analysissupporting
confidence: 76%
“…To evaluate the MWCNT structure of the electrode and to confirm its non-porous nature, scan rate studies were carried out where the log of the peak current was measured against the log of the scan rate. For a typical diffusion-controlled redox process at a working electrode, one would expect a gradient of close to theoretical 0.5 [58]. The results of this work demonstrated a gradient of 0.4 which is close to the theoretical value of 0.5, thus indicating an electron process which was diffusional and demonstrated a non-porous electrode structure [59].…”
Section: Electrochemical Analysissupporting
confidence: 76%
“…In a study conducted by Benjamin Crane et. al., 39 the utility of resazurin as redox mediators was explored for the detection of Escherichia coli with the goal of developing a diagnostic tool for urinary tract infection(Figure 3c). Notably, the study employed bulk modification of screen-printed electrodes during the carbon-graphitic ink screen printing process to incorporate resazurin into the electrodes.…”
Section: Electrochemical Phenotypic Antimicrobial Susceptibility Testingmentioning
confidence: 99%
“…The use of resazurin as dye in AST methodologies is extensive. Combining resazurin with screen-printed electrodes, a platform for the electrochemical antibiotic susceptibility testing of E. coli against gentamicin sulfate was developed [ 47 ]. DPV was also used allowing the determination of antibiotic susceptibility after 90 min, including the steps of inoculation, pre-incubation, and testing.…”
Section: Antibiotic Screening Through Electrochemical Meansmentioning
confidence: 99%