2017
DOI: 10.1080/09540105.2017.1297778
|View full text |Cite
|
Sign up to set email alerts
|

Rapid and ultrasensitive detection of 3-amino-2-oxazolidinone in catfish muscle with indirect competitive enzyme-linked immunosorbent and immunochromatographic assays

Abstract: In this study, we developed an indirect competitive enzyme-linked immunosorbent assay (ic-ELISA) and an immunochromatographic assay to detect the furazolidone metabolite, 3-amino-2oxazolidinone (AOZ). The detection of AOZ was based on the AOZ derivative 3-([2-nitrophenyl]methyleneamino]-2-oxazolidinone (2-NPAOZ). 3-([(3-Carboxyphenyl)methylene]-amino)-2-oxazolidinone (2-CPAOZ) was used as the immunizing hapten and a conjugate of AOZ and glyoxylic acid (AOZ-A) was used as the coating hapten. The monoclonal anti… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
11
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
10

Relationship

5
5

Authors

Journals

citations
Cited by 16 publications
(11 citation statements)
references
References 33 publications
0
11
0
Order By: Relevance
“…Immunochromatographic assay test strips, also known as lateral flow immunoassay (LFIA) test strips are becoming increasingly popular as diagnostic tools for the detection of target analytes because they are simple to use, they are rapid, specific, and sensitive. The major advantages of this method is that all reagents are included on the strip and results can be obtained within 5-10 min (Ding, Liu, Song, Kuang, & Xu, 2017;Kong et al, 2017;Liu et al, 2017;Liu, Xu, Suryoprabowo, Song, & Kuang, 2018b;Li, Liu, Song, & Kuan, 2018).…”
Section: Introductionmentioning
confidence: 99%
“…Immunochromatographic assay test strips, also known as lateral flow immunoassay (LFIA) test strips are becoming increasingly popular as diagnostic tools for the detection of target analytes because they are simple to use, they are rapid, specific, and sensitive. The major advantages of this method is that all reagents are included on the strip and results can be obtained within 5-10 min (Ding, Liu, Song, Kuang, & Xu, 2017;Kong et al, 2017;Liu et al, 2017;Liu, Xu, Suryoprabowo, Song, & Kuang, 2018b;Li, Liu, Song, & Kuan, 2018).…”
Section: Introductionmentioning
confidence: 99%
“…Immunochromatographic assay test strips, also known as lateral flow immunoassay (LFIA) test strips, are becoming increasingly popular as diagnostic tools for detecting target analytes because they are simple to use, rapid, specific, and sensitive. The advantages of this method are that all of the reagents are included in the strip and results can be obtained within 5-10 min (Ding, Liu, Song, Kuang, & Xu, 2017;Kong et al, 2017aKong et al, , 2017bWang, Xie, et al, 2017).…”
Section: Introductionmentioning
confidence: 99%
“…The reaction was stopped with the addition of 2 M sulfuric acid (50 µL/well). Absorbance was measured at 450 nm (Ding, Liu, Song, Kuang, & Xu, 2017). IC 50 and LOD were calculated by a standard curve generated by plotting optical density at 450 nm (OD 450 ) on the y-axis against vitamin B 2 concentration on the x-axis.…”
Section: Development Of Ic-elisamentioning
confidence: 99%