2012
DOI: 10.1007/s11419-012-0138-5
|View full text |Cite
|
Sign up to set email alerts
|

Rapid and sensitive quantification of paraquat and diquat in human serum by liquid chromatography/time-of-flight mass spectrometry using atmospheric pressure photoionization

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
15
0

Year Published

2013
2013
2017
2017

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 22 publications
(15 citation statements)
references
References 27 publications
0
15
0
Order By: Relevance
“…In a study by Wang et al, ESI, APCI, and APPI were compared in the LC‐MS analysis of 17 illicit drugs and their metabolites from oral fluid, and APPI showed the lowest LODs for most of the analytes; APCI and APPI were however observed to be more susceptible to matrix effects than ESI (Wang, Feng, & Chen, ). APPI has also been used for the LC‐MS analysis of paraquat and diquat, which are widespread herbicides and popular suicide agents, in human serum (Yoshioka et al, ). When compared with ESI, APPI showed 7–10 times better sensitivity.…”
Section: Recent Appi Applicationsmentioning
confidence: 99%
“…In a study by Wang et al, ESI, APCI, and APPI were compared in the LC‐MS analysis of 17 illicit drugs and their metabolites from oral fluid, and APPI showed the lowest LODs for most of the analytes; APCI and APPI were however observed to be more susceptible to matrix effects than ESI (Wang, Feng, & Chen, ). APPI has also been used for the LC‐MS analysis of paraquat and diquat, which are widespread herbicides and popular suicide agents, in human serum (Yoshioka et al, ). When compared with ESI, APPI showed 7–10 times better sensitivity.…”
Section: Recent Appi Applicationsmentioning
confidence: 99%
“…Also, the sensitivity of the proposed assay is almost same as those of LC-time of flight-MS [14], LC-electrospray ionization-MS [15] and LC-tandem MS [17]. Although the proposed assay is less sensitive than voltammetry [9] and GC-ion trap-MS [10], these methods required special and complex equipment.…”
Section: Optimization Of Chemiluminescence Conditionsmentioning
confidence: 94%
“…Several methods have been reported for the analysis of paraquat using colorimetry [6], spectrophotometry [7], voltammetry [8], capillary electrophoresis (CE) [9], gas chromatography (GC) [10,11], high-performance liquid chromatography (HPLC) with ultraviolet (UV) detection [12], post-column colorimetric detection [13] and mass spectrometry (MS) [14][15][16][17]. The colorimetry using hydrosulfite as a reagent is very simple and traditional assay for paraquat and has been used for on-site analysis.…”
Section: Introductionmentioning
confidence: 99%
“…PQ DQ HPLC-UV 10 11 LC-TOF-MS 12 GC-MS 13 14 HPLC-UV Paraquat and diquat are most widely used herbicides, but they have significant acute toxicity to humans. The aim of the present study is to develop a high-performance liquid chromatography (HPLC)-chemiluminescence (CL) detection system that allows simultaneous determinations of paraquat and diquat.…”
Section: Pq Dq Pq Dqmentioning
confidence: 99%