2012
DOI: 10.1002/elps.201200057
|View full text |Cite
|
Sign up to set email alerts
|

Rapid and sensitive analysis of three polyphenols in tobacco by CE using homemade C4D with a mini detection cell

Abstract: A rapid, sensitive, and practical CE with C(4) D detection was developed for the analysis of three polyphenols (rutin, scopoletin, and chlorogenic acid) in tobacco samples. The constructed mini detection cell (12 mm × 10 mm × 10 mm) of C(4) D featured with small inner cell volume (∼2 nL), smaller noise (<0.9 mV), repeatability, high strength and durableness. Three polyphenols were ultrasonically extracted with methanol-water (70:30, v/v) solution following SPE cleanup. The CE method was optimized with the runn… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
3
2

Year Published

2013
2013
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 23 publications
1
3
2
Order By: Relevance
“…For K + and Na + , the theoretical plates are about 15 800 and 17 900 plates/m, respectively. This is higher than the published figures , in which K + and Na + were reported to possess 8000 and 13 000 plates/m, respectively. Using the improved C 4 D mini‐cell, the noise was in the range of 0.2∼0.5 mV and changed with different CE buffer solutions.…”
Section: Resultscontrasting
confidence: 75%
See 2 more Smart Citations
“…For K + and Na + , the theoretical plates are about 15 800 and 17 900 plates/m, respectively. This is higher than the published figures , in which K + and Na + were reported to possess 8000 and 13 000 plates/m, respectively. Using the improved C 4 D mini‐cell, the noise was in the range of 0.2∼0.5 mV and changed with different CE buffer solutions.…”
Section: Resultscontrasting
confidence: 75%
“…The reproducibility and stability of the improved minicell used in C 4 D can reach the same level as reported previously [37] and in addition, the smaller inner cell volume contributes to an improvement in the column efficiency. For K + and Na + , the theoretical plates are about 15 800 and 17 900 plates/m, respectively.…”
Section: Evaluation Of the Improved Mini-cell For C 4 Dsupporting
confidence: 81%
See 1 more Smart Citation
“…Other applications include the determination of three polyphenols in tobacco leafs , a set of 14 lanthanides in simulated spent nuclear reactor fuel , peroxycarboxylates in commercial peracetic acid , and PCR products in genetically modified soybeans . Enzymatic assays of myrosinase were evaluated on the basis of sulphate production and its subsequent CE‐C 4 D determination .…”
Section: Applications Of Electrophoresis Methods With Conventional Camentioning
confidence: 99%
“…One of the main polyphenol components of tobacco is rutin, 29-31 whose structure is shown in Figure 5B. 31 According to the measured values of DE, it is evident that the chromogen solution present in tobacco is more resistant to oxidation by hydrogen peroxide than the one present in wine. Such a difference may be due to the chemical structure of these molecules.…”
Section: E264mentioning