1993
DOI: 10.1016/0378-4347(93)80493-n
|View full text |Cite
|
Sign up to set email alerts
|

Rapid and highly sensitive high-performance liquid chromatographic method for the determination of histamine and 3-methylhistamine in biological samples using fluorescamine as the derivatizing agent

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

1997
1997
2008
2008

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 25 publications
(7 citation statements)
references
References 20 publications
0
7
0
Order By: Relevance
“…Intact HA and the metabolites without derivatization are simultaneously separated by a cation-exchange column (Yamatodani et al, 1985;Itoh et al, 1991;Mine et al, 1986;Houdi et al, 1987;Hermann et al, 1993). Although the other types of columns such as the octadesylsilyl column (ODS; Itoh et al, 1992;Allenmark et al, 1985;Ronnberg et al, 1984;Harsing et al, 1986a,b;Tsikas et al, 1993;Hui and Taylor, 1984;van Haaster et al, 1993;Saito et al, 1992;Skofitsch et al, 1981;Devalia et al, 1985;Kasziba et al, 1988) and the cyanopropylsilyl column (Siegel et al, 1990a,b) can be used for the separation, not only is the separation efficiency not very high, but also peak tailing based on adsorption by the resins sometimes occurs. In such a case, an ion-pair reagent (usually acidic compound) is commonly added to the mobile-phase (Vind et al, 1991).…”
Section: Liquid Chromatographymentioning
confidence: 98%
See 3 more Smart Citations
“…Intact HA and the metabolites without derivatization are simultaneously separated by a cation-exchange column (Yamatodani et al, 1985;Itoh et al, 1991;Mine et al, 1986;Houdi et al, 1987;Hermann et al, 1993). Although the other types of columns such as the octadesylsilyl column (ODS; Itoh et al, 1992;Allenmark et al, 1985;Ronnberg et al, 1984;Harsing et al, 1986a,b;Tsikas et al, 1993;Hui and Taylor, 1984;van Haaster et al, 1993;Saito et al, 1992;Skofitsch et al, 1981;Devalia et al, 1985;Kasziba et al, 1988) and the cyanopropylsilyl column (Siegel et al, 1990a,b) can be used for the separation, not only is the separation efficiency not very high, but also peak tailing based on adsorption by the resins sometimes occurs. In such a case, an ion-pair reagent (usually acidic compound) is commonly added to the mobile-phase (Vind et al, 1991).…”
Section: Liquid Chromatographymentioning
confidence: 98%
“…As other pre-column derivatization reagents, fluorescamine (van Haaster et al, 1993(van Haaster et al, , 1994, 4-BrMC (Tsuruta et al, 1987), DBD-F and DBD-PZ (Toyo'oka et al, 2004;Kawanishi et al, 2006Kawanishi et al, , 2007 are also applicable for the determination of HA and related compounds (MHA, MIAA, IAA, etc.). The samples in coronary perfusates, extracts of homogenized rat hearts and supernatants of stimulated peritoneal mast cells were purified and concentrated on cation-exchange columns and derivatized with fluorescamine in borate buffer (pH 9.1) at 40°C for 1 min (van Haaster et al, 1993).…”
Section: Application Of Lc To Biological Specimensmentioning
confidence: 99%
See 2 more Smart Citations
“…As the reaction between OPA and histamine completes within 30 s in the presence of 2-mercaptoethanol at room temperature, pre-column derivatization with OPA is commonly adopted for HPLC-FLD analysis of histamine. However, critical conditions have to be controlled to eliminate the influence of the relative instability of the derivatives [27,28].…”
Section: Introductionmentioning
confidence: 99%