2010
DOI: 10.1080/00387010903321737
|View full text |Cite
|
Sign up to set email alerts
|

Rapid and Direct Spectrofluorometric and Chemometrics Methods for the Simultaneous Determination of Two Dansyl Derivatives

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2011
2011
2019
2019

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(1 citation statement)
references
References 43 publications
0
1
0
Order By: Relevance
“…So, several different approach were developed to solve this problem like simultaneous equation (Pandey et al 2014;Tiwari and Pillai 2011), Q-absorbance ratio (Pandey et al 2014;Thankappan et al 2012), and absorbance ratio (Tiwari and Pillai 2011) method which were used to resolve the overlapping spectrum of conventional spectrophotometry for the simultaneous determination of ET and TC. Recently, chemometrics techniques containing several multivariate calibration calculations (Riahi et al 2010;Sankar et al 2011) in combination with spectrophotometry have been applied to resolve the overlapping spectra of mixtures of drugs in pharmaceuticals because multivariate methods allow to filter interferences of analyzed substance and have several advantages such as lower usage of chemicals, manpower, less time consumed, reasonable accuracy, and precision without chromatographic separation procedures. To the best of our knowledge, there are no publications for the simultaneous determination of ET and TC based on the coupling of UV-Vis spectroscopy and multivariate calibration methods.…”
Section: Introductionmentioning
confidence: 99%
“…So, several different approach were developed to solve this problem like simultaneous equation (Pandey et al 2014;Tiwari and Pillai 2011), Q-absorbance ratio (Pandey et al 2014;Thankappan et al 2012), and absorbance ratio (Tiwari and Pillai 2011) method which were used to resolve the overlapping spectrum of conventional spectrophotometry for the simultaneous determination of ET and TC. Recently, chemometrics techniques containing several multivariate calibration calculations (Riahi et al 2010;Sankar et al 2011) in combination with spectrophotometry have been applied to resolve the overlapping spectra of mixtures of drugs in pharmaceuticals because multivariate methods allow to filter interferences of analyzed substance and have several advantages such as lower usage of chemicals, manpower, less time consumed, reasonable accuracy, and precision without chromatographic separation procedures. To the best of our knowledge, there are no publications for the simultaneous determination of ET and TC based on the coupling of UV-Vis spectroscopy and multivariate calibration methods.…”
Section: Introductionmentioning
confidence: 99%