Rapid analysis of paralytic shellfish toxins and tetrodotoxins by liquid chromatography-tandem mass spectrometry using a porous graphitic carbon column

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
15
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 27 publications
(16 citation statements)
references
References 22 publications
1
15
0
Order By: Relevance
“…Similar precision was obtained by Nzoughet et al in gastropods [25]. The sensitivity obtained was better or of the same order as most other published studies [12,14,24,25,27], and considered totally fit for purpose, though lower than the sensitivities obtained by Leão et al and Turner et al [13,21]. LOQ values of the latter are respectively of 0.9 and 0.8 µg TTX/kg.…”
Section: Discussionsupporting
confidence: 87%
See 1 more Smart Citation
“…Similar precision was obtained by Nzoughet et al in gastropods [25]. The sensitivity obtained was better or of the same order as most other published studies [12,14,24,25,27], and considered totally fit for purpose, though lower than the sensitivities obtained by Leão et al and Turner et al [13,21]. LOQ values of the latter are respectively of 0.9 and 0.8 µg TTX/kg.…”
Section: Discussionsupporting
confidence: 87%
“…For bivalve molluscs, recoveries ranged from 99 to 108%. To the best of our knowledge, the trueness of this method is the best among all in-house-validated procedures [8,16,20,21,23,24]. For gastropods, recoveries ranged from 74 to 80%.…”
Section: Discussionmentioning
confidence: 94%
“…Standard solutions including GTX1-4,6, C1-2, dcGTX2-3, STX, neoSTX, and dcSTX purchased from National Research Council Canada (NRC; Halifax, NS, Canada). STXs’ analysis was performed using a HPLC-FLD system (Waters, Milford, MA, USA) and the post-column method with a slight modification of the process described by Rey et al [ 88 ]. The fluorescence detector operated at an excitation wavelength of 330 nm and emission was scanned at 390 nm.…”
Section: Methodsmentioning
confidence: 99%
“…First, the conditions for hydrophilic interaction chromatography (HILIC)-MS/MS in multiple reaction monitoring (MRM) mode, especially for MS conditions, were optimized for the simultaneous analysis of PSTs and TTXs based on the previously reported methods [47][48][49][50][51][52]. Liquid chromatography (LC) conditions reported by Thomas et al [52] were slightly modified for use in this study (see, Section 4.7).…”
Section: Optimization Of Hilic-ms/ms Conditions For Simultaneous Analmentioning
confidence: 99%