2013
DOI: 10.1007/s10812-013-9783-7
|View full text |Cite
|
Sign up to set email alerts
|

Rapid Analysis of Hemoglobins in Whole Blood by a Light Scattering Method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...

Citation Types

0
8
0

Year Published

2014
2014
2016
2016

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(8 citation statements)
references
References 13 publications
0
8
0
Order By: Relevance
“…The accuracy of this calculation is comparable with the accuracy of the Monte Carlo method, but the calculation times for the methods differ by several orders of magnitude (on personal computers with average technical specifi cations by today's standards, the calculation of the radiation density distribution over the depth of the skin by the method in [23] takes milliseconds). Knowing the total bilirubin concentration in tissues of the dermis, the radiation density distribution over the depth of the dermis, and the illumination of the skin of the patient E(0, λ), using formula (3) we can calculate the rate of transformation of ZZ-bilirubin to the nontoxic and water-soluble isomer LR that is provided by the specifi c phototherapy system.…”
mentioning
confidence: 98%
See 4 more Smart Citations
“…The accuracy of this calculation is comparable with the accuracy of the Monte Carlo method, but the calculation times for the methods differ by several orders of magnitude (on personal computers with average technical specifi cations by today's standards, the calculation of the radiation density distribution over the depth of the skin by the method in [23] takes milliseconds). Knowing the total bilirubin concentration in tissues of the dermis, the radiation density distribution over the depth of the dermis, and the illumination of the skin of the patient E(0, λ), using formula (3) we can calculate the rate of transformation of ZZ-bilirubin to the nontoxic and water-soluble isomer LR that is provided by the specifi c phototherapy system.…”
mentioning
confidence: 98%
“…The possibility for noninvasive determination of the radiation density in the tissue E(z, λ) was demonstrated for the fi rst time in [17,23], where it was proposed to use measurements of the spectral diffuse refl ection coeffi cient for the tissue, R(λ), representing the ratio of the diffuse radiation fl ux refl ected by the medium to the directional radiation fl ux incident on it. The basis for this is the dependence of the penetration depth of light into the tissue on λ.…”
mentioning
confidence: 99%
See 3 more Smart Citations