1992
DOI: 10.1016/0168-583x(92)95971-s
|View full text |Cite
|
Sign up to set email alerts
|

Ramsey technique applied in a Penning trap mass spectrometer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
43
0

Year Published

2004
2004
2023
2023

Publication Types

Select...
5
4

Relationship

3
6

Authors

Journals

citations
Cited by 65 publications
(45 citation statements)
references
References 12 publications
0
43
0
Order By: Relevance
“…A quadrupole rf drive is then applied to convert the initial, low frequency (∼kHz) magnetron motion into high frequency (∼MHz) reducedcyclotron motion, resulting in an increase in the rotational energy of the ions. This is done using either a single rf pulse (traditional TOF-ICR [37,38]) or with a two-pulse sequence (Ramsey TOF-ICR [39][40][41]), that enables a factor of ∼3 increase in precision over the traditional TOF-ICR measurement in the same amount of time.…”
Section: Experimental Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…A quadrupole rf drive is then applied to convert the initial, low frequency (∼kHz) magnetron motion into high frequency (∼MHz) reducedcyclotron motion, resulting in an increase in the rotational energy of the ions. This is done using either a single rf pulse (traditional TOF-ICR [37,38]) or with a two-pulse sequence (Ramsey TOF-ICR [39][40][41]), that enables a factor of ∼3 increase in precision over the traditional TOF-ICR measurement in the same amount of time.…”
Section: Experimental Methodsmentioning
confidence: 99%
“…3 (a). The Ramsey excitation scheme results in an interference pattern [39][40][41]. A Ramsey resonance for 113 In + from this work, where a 300-900-300 ms on-off-on excitation pattern was used, is shown in Fig.…”
Section: Experimental Methodsmentioning
confidence: 99%
“…The ions of interest were then excited by applying a quadrupolar RF electric field at a frequency near the cyclotron frequency of the ion [14]. A Ramsey excitation scheme [15,16] was employed with two 150 ms long RF excitation pulses separated by 450 ms long wait time. The ions were then ejected from the trap and directed to a multi-channel plate (MCP) detector where the TOF was recorded.…”
Section: Experiments Descriptionmentioning
confidence: 99%
“…The Ramsey TOF-ICR technique was suggested more than 20 years ago [35] as a possible way to improve the precision of nuclear mass determinations. The prerequisite for the Ramsey method is an understanding of the observed TOF cyclotron resonance curves using time-separated oscillatory fields.…”
Section: The Achievable Relative Precision Of Pmts With the Tof-icr Tmentioning
confidence: 99%