2015
DOI: 10.1002/jrs.4681
|View full text |Cite
|
Sign up to set email alerts
|

Raman spectroscopy of CaM2+Ge2O6(M2+ = Mg, Mn, Fe, Co, Ni, Zn) clinopyroxenes

Abstract: The Raman spectra of Ge‐clinopyroxenes CaM2+Ge2O6 (M2+ = Mg, Mn, Fe, Co, Ni, Zn), general formula M2M1T2O6, are reported for the first time. Their spectral features are discussed in comparison with corresponding Si‐pyroxenes. The vibrational wavenumbers of germanates may be roughly obtained by a scale factor of about ~0.8 by those of the corresponding silicates, due to the Ge‐Si mass difference. The main peaks in the germanate Raman spectra at ~850 and ~540 cm−1 may be related to Ge‐O tetrahedral stretching an… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
20
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 28 publications
(23 citation statements)
references
References 26 publications
3
20
0
Order By: Relevance
“…Therefore, the Raman spectra are almost identical in all samples. According to previous studies, the Raman shift at <300 cm −1 could be attributed to translations of SiO 4 tetrahedron, the peak at 300–450 cm −1 could be assigned to motions of the cations in the M(2) and M(1) sites that were related with tetrahedral chain motion and tilting tetrahedron. Moreover, the Raman shifts in the region of 225‐303, 360, 450‐600, 666, and 1011 cm −1 can be attributed to the O–Li–O bending and Li–O stretching vibrations, the O–Si–O vibrations, the stretching/bending modes of the Si–O–Si bonds, and O–Si–O stretching modes, respectively.…”
Section: Resultsmentioning
confidence: 75%
“…Therefore, the Raman spectra are almost identical in all samples. According to previous studies, the Raman shift at <300 cm −1 could be attributed to translations of SiO 4 tetrahedron, the peak at 300–450 cm −1 could be assigned to motions of the cations in the M(2) and M(1) sites that were related with tetrahedral chain motion and tilting tetrahedron. Moreover, the Raman shifts in the region of 225‐303, 360, 450‐600, 666, and 1011 cm −1 can be attributed to the O–Li–O bending and Li–O stretching vibrations, the O–Si–O vibrations, the stretching/bending modes of the Si–O–Si bonds, and O–Si–O stretching modes, respectively.…”
Section: Resultsmentioning
confidence: 75%
“…The most prominent bands in the wavenumber range 500-900 cm -1 can be assigned to the vibrational modes of the tetrahedral GeO 4 units [28]. They are similar to the equivalent SiO 4 modes reported for spodumene and related silicates exhibiting the pyroxene structure type [28,29], which are shifted to higher wavenumbers.…”
Section: Raman Spectramentioning
confidence: 83%
“…In germanates, we find similar features albeit downshifted in energy . The strong peaks at ~670 and ~1010 cm −1 in silicates have their counterparts at ~550 and ~850 cm −1 in germanates, respectively . In germanates, the peak corresponding to that at about 1010 cm −1 in silicates is accompanied by a second peak at lower intensity.…”
Section: Resultsmentioning
confidence: 99%
“…Natural diopside, with composition CaMg 0.93 Fe 0.07 Si 2 O 6 , synthetic CaCoSi 2 O 6 and CaCoGe 2 O 6 single crystals were loaded in the diamond anvil cell for the experiments. CaMgGe 2 O 6 was available only as a polycrystalline material, and a few crystallites (average size 8–10 μm) were loaded in the P ‐chamber. Therefore, the absolute intensities of the Raman modes in CaMgGe 2 O 6 could be affected by the orientation of the crystallites.…”
Section: Experimental Methodsmentioning
confidence: 99%