2000
DOI: 10.1002/(sici)1097-4555(200003)31:3<157::aid-jrs513>3.0.co;2-2
|View full text |Cite
|
Sign up to set email alerts
|

Raman and infrared spectra, conformational stability, normal coordinate analysis andab initio calculations of 3-chloro-1-butene

Abstract: The Raman and infrared spectra (3300-30 cm −1 ) of gaseous and solid 3-chloro-1-butene, H 2 C CHCCl (CH 3 )H, were recorded. Additionally, the Raman spectrum (3300-30 cm −1 ) of the liquid was recorded. All three conformers were observed in the fluid phases and the conformer with the hydrogen atom eclipsing the double bond (HE form) was identified as the most predominant. From variable-temperature measurements in liquified xenon, the enthalpy differences between the HE form and the two less stable conformers, … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
6
0

Year Published

2001
2001
2007
2007

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 8 publications
(7 citation statements)
references
References 15 publications
1
6
0
Order By: Relevance
“…An early IR study showed that it exists in at least two forms, and the ED study found three conformers, with the major form being 76% ± 10% at 20 °C, with the proportion of this form decreasing to 62% ± 10% at 180 °C . As part of a more recent vibrational spectroscopic study, the MP2/6-311++G**-calculated energy differences for the conformers were obtained, and are in agreement with other calculated relative energies (see below). However, this study also reported variable-temperature infrared studies using xenon solutions of 1 .…”
Section: 3-chloro-1-butene (1)supporting
confidence: 80%
“…An early IR study showed that it exists in at least two forms, and the ED study found three conformers, with the major form being 76% ± 10% at 20 °C, with the proportion of this form decreasing to 62% ± 10% at 180 °C . As part of a more recent vibrational spectroscopic study, the MP2/6-311++G**-calculated energy differences for the conformers were obtained, and are in agreement with other calculated relative energies (see below). However, this study also reported variable-temperature infrared studies using xenon solutions of 1 .…”
Section: 3-chloro-1-butene (1)supporting
confidence: 80%
“…As opposed to the case of 3-chloro-1-butene, where the calculated ab initio energy differences between the conformers were grossly overestimated compared to the experimental enthalpy values, the predicted ab initio energy differences (Table ) for 3-fluoro-1-butene have more realistic values. However, this is achieved only with the relatively large basis set (MP2/6-311+G(d,p)).…”
Section: Discussionmentioning
confidence: 65%
“…e Frequencies are taken from the infrared spectrum of the gas, except the ones in parentheses, which are taken from the infrared spectrum of the liquid or sample dissolved in liquid xenon. As opposed to the case of 3-chloro-1-butene, 21 where the calculated ab initio energy differences between the conformers were grossly overestimated compared to the experimental enthalpy values, the predicted ab initio energy differences (Table 2) for 3-fluoro-1-butene have more realistic values. However, this is achieved only with the relatively large basis set (MP2/ 6-311+G(d,p)).…”
Section: Discussionmentioning
confidence: 78%
See 2 more Smart Citations