2008
DOI: 10.1007/bf03179351
|View full text |Cite
|
Sign up to set email alerts
|

Radiotherapy DICOM packet sniffing

Abstract: The Digital Imaging and Communications in Medicine (DICOM) standard is meant to allow communication of medical images between equipment provided by different vendors, but when two applications do not interact correctly in a multi-vendor environment it is often first necessary to demonstrate non-compliance of either the sender or the receiver before a resolution to the problem can be progressed. Sometimes the only way to do this is to monitor the network communication between the two applications to find out wh… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0
1

Year Published

2011
2011
2018
2018

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 4 publications
(1 reference statement)
0
2
0
1
Order By: Relevance
“…The shift tolerances were chosen based on phantom measurements that indicated they provided sufficient spatial localization for stereotaxy. 19 The primary treatment techniques are dynamic conformal arcs and static shaped beams. A manual adjustment of the couch longitudinal and lateral position is used to restore patient positioning found to be out of optical tolerance after couch rotation; only very rarely is the motorized couch vertical movement utilized.…”
Section: Iia Clinical Treatment Regimementioning
confidence: 99%
See 1 more Smart Citation
“…The shift tolerances were chosen based on phantom measurements that indicated they provided sufficient spatial localization for stereotaxy. 19 The primary treatment techniques are dynamic conformal arcs and static shaped beams. A manual adjustment of the couch longitudinal and lateral position is used to restore patient positioning found to be out of optical tolerance after couch rotation; only very rarely is the motorized couch vertical movement utilized.…”
Section: Iia Clinical Treatment Regimementioning
confidence: 99%
“…Table II lists the standard deviations of the distributions of the ExacTrac reported coordinates about the actual coordinates inferred from the full clinical data set under the standard pass conditions of 0.7 mm and 0.5 , which phantom based measurements indicated provided sufficient spatial localization for stereotaxy. 19 The quoted interval is the 95% confidence interval. We define the derived value q as the difference in quadrature between the average of the r values in the plane of couch rotation and the value of r perpendicular to the plane, which is calculated according to Eq.…”
Section: Iiib Clinical Data Setmentioning
confidence: 99%
“…Diese mögli-chen Variationen des Standards bereits auf Bilddatenebene können besonders beim Datenaustausch bzw. bei der herstellerunabhängigen Visualisierung Probleme bereiten[1].…”
unclassified