The platform will undergo maintenance on Sep 14 at about 7:45 AM EST and will be unavailable for approximately 2 hours.
2021
DOI: 10.1097/sle.0000000000000991
|View full text |Cite
|
Sign up to set email alerts
|

Radiopaque Fiducials Guiding Laparoscopic Resection of Liver Tumors

Abstract: Background: Minimal invasive laparoscopic resection of liver tumors is less traumatic compared with open surgical resection and may be a better option for many patients. However, localization of intrahepatic tumors remains a challenge. Availability of hybrid operating rooms, equipped for high performance radiologic imaging, allows for new methods of surgical navigation. Methods: Twelve patients planned for laparoscopic resection of liver tumors were included. Before res… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0
1

Year Published

2022
2022
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 12 publications
0
2
0
1
Order By: Relevance
“…Their method had an acceptable degree of accuracy (maximum error of 2.5 mm) in experiments using a phantom liver and was subsequently successfully applied in a laparoscopic resection of a hepatocellular carcinoma in a 50‐year‐old patient. Falkenberg et al also utilized intraoperative fluoroscopy for guidance during resection 48 . They placed radiopaque fiducials (coils and gold rods) near the tumor to help guide surgeons during resection.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Their method had an acceptable degree of accuracy (maximum error of 2.5 mm) in experiments using a phantom liver and was subsequently successfully applied in a laparoscopic resection of a hepatocellular carcinoma in a 50‐year‐old patient. Falkenberg et al also utilized intraoperative fluoroscopy for guidance during resection 48 . They placed radiopaque fiducials (coils and gold rods) near the tumor to help guide surgeons during resection.…”
Section: Methodsmentioning
confidence: 99%
“…Fiducials (white patches on the image) are used to accurately overlay the images. Image source 48. of this has been demonstrated in thoracic surgery for the resection and ablation of pulmonary metastases 70.…”
mentioning
confidence: 99%
“…Der erste Ansatz nutzt initial eine oberflächenbasierte Registrierung mittels bestimmter Landmarken oder intraoperativem Oberflächenscanning [40,41]. Ein andere Ansatz verwendet intraoperative Bildgebungen wie das Cone-Beam-CT oder den Ultraschall, um die Registrierung zu präzisieren [42,43]. Die operations-und atembedingten Deformierungen insbesondere der intrahepatischen Strukturen werden bei beiden Ansätzen mittels biomechanischer Berechnungen simuliert und auf die Simulation übertragen [44,45].…”
Section: üBersichtunclassified