1972
DOI: 10.1364/ao.11.000135
|View full text |Cite
|
Sign up to set email alerts
|

Radiometer for Remote Sounding of the Upper Atmosphere

Abstract: The pressure-modulated CO(2) radiometer is a new kind of instrument capable of making temperature soundings in the 40-80-km region of the earth's atmosphere. It is intended to be mounted on a polar-orbiting satellite, where it will give global coverage of the upper atmosphere in a region that is not well understood at present but that is, as rocket soundings show, clearly the seat of many interesting and vigorous phenomena. The new technique employs a cell containing carbon dioxide as a filter. The pressure an… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0

Year Published

1973
1973
2021
2021

Publication Types

Select...
4
4
2

Relationship

0
10

Authors

Journals

citations
Cited by 47 publications
(10 citation statements)
references
References 11 publications
0
10
0
Order By: Relevance
“…A NH 3 sensor based on this method was found to be 140 times less sensitive to N 2 O contaminant gas, even though the spectral absorption of N 2 O is significantly stronger than the spectral absorption of NH 3 in the band used. Taylor et al (1972) provide details of a similar system, intended to measure remotely (from a satellite) the temperature of the upper atmosphere from the spectral transmission of CO 2 .Th e system gathered light reflected from the earths atmosphere, and passed it though a pressure Fig. 6.…”
Section: Optical Methods Of Detectionmentioning
confidence: 99%
“…A NH 3 sensor based on this method was found to be 140 times less sensitive to N 2 O contaminant gas, even though the spectral absorption of N 2 O is significantly stronger than the spectral absorption of NH 3 in the band used. Taylor et al (1972) provide details of a similar system, intended to measure remotely (from a satellite) the temperature of the upper atmosphere from the spectral transmission of CO 2 .Th e system gathered light reflected from the earths atmosphere, and passed it though a pressure Fig. 6.…”
Section: Optical Methods Of Detectionmentioning
confidence: 99%
“…In this study, the cell length and temperature are same for each channel and every SSU sensors [Television and Infrared Observation Satellite (TIROS)-N, NOAA-6, NOAA-7, NOAA-8, NOAA-9, NOAA-11, and NOAA-14], taken as 1 cm and 302.6 K, respectively. The weighting function peak height for a CO 2 PMR (Taylor et al 1972) may be analytically expressed as The uncertainty on these three parameters induces an effect of less than 0.01% on BT changes (Brindley et al 1999), and can be negligible compared to the impact of the cell pressure changes, which can be on an order of 1 K. The assessment of the effects of the cell drifts upon measured BTs is discussed in section 5.…”
Section: Ssu Spectral Response Functionsmentioning
confidence: 99%
“…These bands have been used, for example by Walshaw (1960) and Vigroux (1969) for the determination of the vertical distribution of 0 3 and for satellite vertical temperature distributions from CO e (see e.g. Taylor et al, 1972;Abel et al, 1970;Houghton and Smith, 1970). Williamson and Houghton (1966) have described balloon measurements of the 6.3/~ HeO emission band~ Rotational emission from H20 is important in the 18# region.…”
Section: Thermal Emissionsmentioning
confidence: 99%