1970
DOI: 10.1016/s0039-128x(70)80053-8
|View full text |Cite
|
Sign up to set email alerts
|

Radioimmunoassay of plasma estrone and estradiol

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

2
50
0

Year Published

1973
1973
1999
1999

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 238 publications
(52 citation statements)
references
References 15 publications
2
50
0
Order By: Relevance
“…In addition, the Sephadex LH-20 chromatographic system used in the estrogen assays reliably separates C19 and C2, plasma steroids from the E1 and E. fractions (4 40±5) (4). The concentrations of E2 in peripheral plasma agree with values previously reported by us (1, 4) and others (9,11,12). Spermatic venous E1 concentrations ranged from 135 pg/ml to 665 pg/ml.…”
Section: Introductionsupporting
confidence: 91%
“…In addition, the Sephadex LH-20 chromatographic system used in the estrogen assays reliably separates C19 and C2, plasma steroids from the E1 and E. fractions (4 40±5) (4). The concentrations of E2 in peripheral plasma agree with values previously reported by us (1, 4) and others (9,11,12). Spermatic venous E1 concentrations ranged from 135 pg/ml to 665 pg/ml.…”
Section: Introductionsupporting
confidence: 91%
“…As a metabolite of DHEA, which might be of significance, S-androstene-3B, 17/j'-diol (adiol) was chosen. This weak androgen is present in the plasma of fertile women in a concentration of 6~9Ong~IOOml [32]. Circulating DHEA accounts for one-third of the total adiol production [23].…”
Section: * Senior Research Fellow Of the Dutch Organisation For Cancementioning
confidence: 99%
“…Furthermore, the solid-phase extraction is considered to be more practical than the conventional method due to its simple procedure. Notwithstanding that, the solid-phase extraction cannot separate estradiol-17β and estrone as shown in Table 1, but the conventional method can [3,4,7,11]. Therefore, crossreactivity of antibody is a key factor in immunoassay of estrogens with the solid-phase extract.…”
Section: Discussionmentioning
confidence: 99%
“…eripheral estradiol-17β concentration is an important diagnostic index for the follicular preparation method for measuring estradiol-17β levels in cattle [3,4,7]. However, the validated preparation method for radioimmunoassay of estradiol-17β is still complicated.…”
mentioning
confidence: 99%
See 1 more Smart Citation