Radiographic Evaluation of Bone Remodeling Around Osseointegration Implants Among Transfemoral Amputees

Abstract: Objectives: To examine periprosthetic bone remodeling among the recipients of 2 types of lower-limb osseointegrated systems, the Integral Leg Prosthesis (ILP) and the Osseointegration Prosthetic Limb (OPL) type A, over a >24-month period. Design: Retrospective cohort study. Setting: Private hospital, with a specialized osseointegration unit. Patients: Twenty-e… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
12
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 18 publications
(18 citation statements)
references
References 16 publications
2
12
0
Order By: Relevance
“…The POP titanium alloy (Ti6Al4V) femoral stem was 100 mm long (Figure 1) with a tapered, proximal region with splines to reduce stress-shielding and a distal osteotomy collar to cap the end of the bone. 20,25 A circumferential titanium porous coating (P-Squared, P 2TM ) was present on the distal 30 mm of the stem and on the collar. Implantation of the POP device was performed in two surgical stages.…”
Section: Device Description and Surgical Proceduresmentioning
confidence: 99%
See 2 more Smart Citations
“…The POP titanium alloy (Ti6Al4V) femoral stem was 100 mm long (Figure 1) with a tapered, proximal region with splines to reduce stress-shielding and a distal osteotomy collar to cap the end of the bone. 20,25 A circumferential titanium porous coating (P-Squared, P 2TM ) was present on the distal 30 mm of the stem and on the collar. Implantation of the POP device was performed in two surgical stages.…”
Section: Device Description and Surgical Proceduresmentioning
confidence: 99%
“…This would provide clinicians with an enhanced data set to better evaluate the integrity of the bone-implant interface and take preventative measures to avoid possible implant failure. 25,26 The goal of this study was to develop a proficient, reproducible method using three-dimensional models constructed from clinical computed tomography (CT) scans to perform an objective in vivo analysis of bone morphological changes around the POP device in transfemoral amputees. CT imaging is now used as the gold standard for analyzing morphology measurements in three-dimensional (3D) reconstructions of bone 27,28 and has the potential to provide a more complete and accurate analysis of bone remodeling that is occurring around OI devices over time.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…A major breakthrough was the introduction of press-fit Endo-Exo- Prosthesis (EEPs) by Hans Grundei et al who applied porous cobalt chromium metal stem as the intramedullary implant ( Mittelmeier et al, 1997 ). Dr. Al Muderis and co-workers later developed the Osseointegrated Prosthetic Limb (OPL) system, in which the implant material was changed from cobalt-chromium to titanium ( Thomson et al, 2019 ). The press-fit systems shortened the time for surgery and rehabilitation, becoming favorable choices for patients and surgeons in recent years ( Hoellwarth et al, 2020 ).…”
Section: Introductionmentioning
confidence: 99%
“…Furthermore, reduction of periprosthetic bone mineral density (BMD) may lead to complications such as aseptic loosening, infection, and fractures (Electricwala et al 2016;Marks 2009). Hence, several empirical studies have been conducted to monitor the periprosthetic bone remodeling around osseointegrated trans-femoral prostheses (Nebergall et al 2012;Thomson et al 2019).…”
Section: Introductionmentioning