Radiochromic film for medical radiation dosimetry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

6
196
0
15

Year Published

2008
2008
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 292 publications
(218 citation statements)
references
References 141 publications
6
196
0
15
Order By: Relevance
“…[1][2][3][4][5][6][7] While many of the current polymer systems are utilized for two-or three-dimensional dose representation, high spatial resolution offers potential for successful implementation in point-based measurements. Radiochromic materials commercially available in GAFCHROMIC ® films ͑International Specialty Products, Wayne, NJ͒ have the desired high spatial resolution [8][9][10] and are able to provide sufficient signal from a subcubic millimeter volume. 11,12 Furthermore, they can be made relatively energy independent, [13][14][15] and have been shown to respond in real time.…”
Section: Introductionmentioning
confidence: 99%
“…[1][2][3][4][5][6][7] While many of the current polymer systems are utilized for two-or three-dimensional dose representation, high spatial resolution offers potential for successful implementation in point-based measurements. Radiochromic materials commercially available in GAFCHROMIC ® films ͑International Specialty Products, Wayne, NJ͒ have the desired high spatial resolution [8][9][10] and are able to provide sufficient signal from a subcubic millimeter volume. 11,12 Furthermore, they can be made relatively energy independent, [13][14][15] and have been shown to respond in real time.…”
Section: Introductionmentioning
confidence: 99%
“…Then, the optical density (OD) was associated with the absorbed dose, following Equation 1, in which the optical density was defined [12,16], as:…”
Section: Digitization and Treatment Of The Calibration Datamentioning
confidence: 99%
“…in which I0 is the R intensity from RGB digital image of the non-irradiated film, and I is the R intensity of the irradiated film [12,16]. The standard deviations of the optical densities of the exposed and unexposed films were calculated as described by Devic et al [12,13] as follows: …”
Section: Digitization and Treatment Of The Calibration Datamentioning
confidence: 99%
See 1 more Smart Citation
“…Dans cette optique, nous avons utilisé des films radiochromiques XR-RV3-Gafchromic ® positionnés contre la peau des patients pendant des procédures radiologiques supposées à risque, afin de connaître rapidement en fin d'examen la dose cutanée maximale et la cartographie de la distribution dosimétrique en fonction des différentes incidences utilisées. Ce type de film auto-développant a en effet montré ses avantages par rapport aux films radiographiques et la grande précision dosimétrique que l'on peut en extraire (Niroomand-Rad et al, 1998 ;Butson et al, 2003 ;Dini et al, 2005). …”
Section: Introduction / Contexteunclassified