Radiopharmaceuticals for Positron Emission Tomography 1993
DOI: 10.1007/978-94-015-8204-9_2
|View full text |Cite
|
Sign up to set email alerts
|

Radiochemistry Automation for PET

Abstract: ABS1RACT. Methodological approaches to automation for PET radiochemistry are discussed. Detailed examples of automation using i) simple remote control. ii) PLC-operated devices and iii) computer-controlled devices are described for the syntheses of llC-. 150_ and 18F-Iabelled radiopharmaceuticals. Approaches to robot-based automation are also discussed and exemplified. 45G.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
26
0

Year Published

1997
1997
2020
2020

Publication Types

Select...
5
2
1

Relationship

1
7

Authors

Journals

citations
Cited by 43 publications
(26 citation statements)
references
References 39 publications
0
26
0
Order By: Relevance
“…Wholebody glucose uptake, a measurement of insulin sensitivity, was calculated from the glucose infusion rate after correcting for changes in the glucose pool size [16]. [18]. Sterility and pyrogenity tests for water, and chromatographic analysis for gases were performed to verify the purity of the products.…”
Section: Methodsmentioning
confidence: 99%
“…Wholebody glucose uptake, a measurement of insulin sensitivity, was calculated from the glucose infusion rate after correcting for changes in the glucose pool size [16]. [18]. Sterility and pyrogenity tests for water, and chromatographic analysis for gases were performed to verify the purity of the products.…”
Section: Methodsmentioning
confidence: 99%
“…We produced 15 O using a low-energy deuteron accelerator Cyclone 3 (Ion Beam Application, Louvain-la-Neuve, Belgium). To produce [ 15 O]H 2 O, we used dialysis techniques in a continuously working water module [9,10]. In order to verify the purity of the products, we carried out sterility and pyrogenity tests for water, and chromatographic analysis for gases.…”
Section: Production Of [15o]h2omentioning
confidence: 99%
“…Thereafter, physiological hyperinsulinemia (1 mU/kg/min) 26 was started and continued for 60 min before the second intravenous infusion of adenosine 27 15 O-labelled water was produced using dialysis techniques in a continuously working water module. 28 Sterility and pyrogenity tests for water and chromatographic analysis for gases were performed to verify the purity of the products.…”
Section: Methodsmentioning
confidence: 99%