Radio‐guided surgery: advantages of a new portable γ‐camera (Sentinella®) for intraoperative real time imaging and detection of sentinel lymph nodes in cutaneous malignancies

Abstract: The portable γ-camera is an innovative imaging technique, reliable and providing additional information in the detection of SLN. Therefore SLNE with intraoperative γ-camera use is an attractive option to improve the detection of SLN in cutaneous malignancies and could help to reduce false negative SLN results.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
16
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
5
5

Relationship

0
10

Authors

Journals

citations
Cited by 43 publications
(16 citation statements)
references
References 23 publications
0
16
0
Order By: Relevance
“…However, in recent years, portable gamma cameras have been developed and have been introduced to the operating room. These enable fast and reliable detection and localization of SLNs [147,148]. Additionally, a 3D system has been developed [98,149] that allows the surgeon to visualize the SLN in real-time using 3D navigation.…”
Section: Radioactive Clinical Wastementioning
confidence: 99%
“…However, in recent years, portable gamma cameras have been developed and have been introduced to the operating room. These enable fast and reliable detection and localization of SLNs [147,148]. Additionally, a 3D system has been developed [98,149] that allows the surgeon to visualize the SLN in real-time using 3D navigation.…”
Section: Radioactive Clinical Wastementioning
confidence: 99%
“…Aside from fhSPECT navigation, there are other possibilities for intraoperative sentinel node imaging such as portable gamma cameras [21][22][23][24] and fusion ultrasound/…”
Section: Emerging Developments For Sln Biopsy In Hn Cancermentioning
confidence: 99%
“…This device is able to discriminate between two different energy peaks and display them separately on the screen, allowing the use of external pointers such as 153 Gd, 133 Ba or 125 I. Systems such as Sentinella S102 (Oncovision-GEM Imaging, Valencia, Spain), LumaGEM ® (Gamma Medica Ideas, CA, USA) and eZ-SCOPE (Anzai Medical, Tokio, Japan) are all particularly usable in problematic cases detected during presurgical assessment or even when the lymphoscintigraphy is not available [93,94]. In the operation room, the portable gamma camera's detector arm can be placed above the previously marked skin locations, thanks to the help of a cross-shaped laser beam projected on the skin of the patient, simultaneously with display on the screen of the portable gamma camera.…”
Section: Lymphoscintigraphy Improves the Accuracy Of Sentinel Lymph Nmentioning
confidence: 99%