2014
DOI: 10.1016/j.apradiso.2013.07.011
|View full text |Cite
|
Sign up to set email alerts
|

Radiation therapy dosimetry system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
3
0
3

Year Published

2014
2014
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(7 citation statements)
references
References 20 publications
0
3
0
3
Order By: Relevance
“…However, larger quantities of radioisotopes having short half-lives could be administered in order to attain a prolonged stable signal. This ultimately leads to excessive radiation attenuation by tissues [3,4] and high diagnostic patient doses [68]. Lack of sensitivity stability over a prolonged duration could limit the application of the CLI imaging technique to procedures like total body tomography; imaging of the whole body is done—not only a specific region of interest [69].…”
Section: Charge Couple Devices (Ccd)/charge Metal Oxide Semiconducmentioning
confidence: 99%
See 1 more Smart Citation
“…However, larger quantities of radioisotopes having short half-lives could be administered in order to attain a prolonged stable signal. This ultimately leads to excessive radiation attenuation by tissues [3,4] and high diagnostic patient doses [68]. Lack of sensitivity stability over a prolonged duration could limit the application of the CLI imaging technique to procedures like total body tomography; imaging of the whole body is done—not only a specific region of interest [69].…”
Section: Charge Couple Devices (Ccd)/charge Metal Oxide Semiconducmentioning
confidence: 99%
“…Today, radiation is used for carrying out radiotherapeutic or imaging procedures like Computed Tomography (CT)—in the field of medicine [2]. However, during its applications, there has to be precaution since excessive radiation attenuation by human tissue may result into high absorbed dose values [3,4]. This could be a root cause of secondary malignancies [4].…”
Section: Introductionmentioning
confidence: 99%
“…Pemanfaatan sinar gamma dalam radioterapi memerlukan pengukuran dosis yang tepat untuk mencegah dan meminimalkan efek samping pada pengguna maupun pekerja terapi. Dosimetri radiasi berperan penting dalam kualiti kontrol proses radiasi (Rivera-Montalvo, 2014). Dosimeter berbasis larutan kimia ferrous sulfate yang disebut juga dengan dosimeter Fricke merupakan dosimeter standar yang telah digunakan dalam dosimetri radiasi.…”
Section: Pendahuluanunclassified
“…Rentang dosis yang dapat diukur TLD bergantung pada sensitivitas dan respon nanomaterialnya, tidak dapat mengukur dosis rendah dan dosis tinggi (Salah, 2011). Berbagai nanomaterial TLD didoping dengan cerium untuk meningkatkan karakteristiknya (Ravikumar, dkk;2014;Zahedifar, dkk., 2013). Oksida cerium (CeO2) telah dikaji untuk sensor radiasi sinar gamma dalam bentuk thick film p-n jucntion (Arshak dan Korostynska, 2004…”
Section: Pendahuluanunclassified
“…One can find the dose rate in real cases, just simply, by multiplying Equation (2) with the known flux (#/cm 2 -sec), γ-ray energy, E (MeV) and linear mass absorption coefficient µ ρ (cm 2 /g) of the dose receiving material. Equation (2) shows that the maxima in the dose rate can occur only when the solid angle subtended by the rectangular surface of the package with point isotropic source has the maxima. The solid angle subtended by any area at a distance r from a point isotropic source can be given by [9] …”
Section: Theoretical Modelmentioning
confidence: 99%