1998
DOI: 10.1007/bf02680479
|View full text |Cite
|
Sign up to set email alerts
|

Radiation scattering by finite dielectric cyclinders

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
5
0

Year Published

2010
2010
2017
2017

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 13 publications
0
5
0
Order By: Relevance
“…However, even if the values listed in Table I are reasonable great care must be taken when comparing these values with the other literature data. 13 This is because the obtained excitation bands ͑discussed in the next paragraph͒ can be distorted by photonics effects induced by the porous matrix, 15,16 which should also be taken into account when considering absolute values describing excitation ͑de-cay͒ spectra of Tb ions in similar matrices. Such a detailed discussion related to this issue will be given in our next paper.…”
Section: Resultsmentioning
confidence: 99%
“…However, even if the values listed in Table I are reasonable great care must be taken when comparing these values with the other literature data. 13 This is because the obtained excitation bands ͑discussed in the next paragraph͒ can be distorted by photonics effects induced by the porous matrix, 15,16 which should also be taken into account when considering absolute values describing excitation ͑de-cay͒ spectra of Tb ions in similar matrices. Such a detailed discussion related to this issue will be given in our next paper.…”
Section: Resultsmentioning
confidence: 99%
“…There is no an analytic solution of the scattering problem by the finite dielectric cylinder. Moreover, the numerical methods [4,5,6] are complicated when the aspect ratio is large. From the other hand, the scattering amplitude by the infinite cylinder is expressed analytically in a closed form [7,8].…”
Section: Introductionmentioning
confidence: 99%
“…It should be noted that DDs of separate cylinders were exceedingly sensitive to their geometric dimensions and dielectric properties and to the radiation wavelength. For example, it was found [3] that the DD was stretched forward upon decreasing the wavelength of the incident radiation. Figure 2 shows DDs of separate cylinders as functions of incident radiation wavelength and cylinder dielectric permeability.…”
mentioning
confidence: 98%
“…4. Directional diagram of a multimer of seven cylinders of diameter 100 nm and length 1500 nm; radius of the circle on which the cylinder centers are situated in the multimer, 140 (1, 3) and 100 nm (2, 4); cylinder refractive index n = 1.76 (1, 2) and 1.59 (3,4); λ = 300 nm.…”
mentioning
confidence: 99%
See 1 more Smart Citation