2022
DOI: 10.1088/1361-6498/ac32a2
|View full text |Cite
|
Sign up to set email alerts
|

Radiation exposure in the intra-arterial nimodipine therapy of subarachnoid hemorrhage related cerebral vasospasm

Abstract: The selective intra-arterial nimodipine application for the treatment of cerebral vasospasm (CVS) in patients after spontaneous subarachnoid hemorrhage (sSAH) is widely employed. The purpose of this study is to examine the radiation exposure and to determine local diagnostic reference levels (DRLs) of intra-arterial nimodipine therapy. In a retrospective study design, DRLs and achievable dose (AD) were assessed for all patients undergoing (I) selective intra-arterial nimodipine application or (II) additional m… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

1
0
0
2

Year Published

2023
2023
2023
2023

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 28 publications
(28 reference statements)
1
0
0
2
Order By: Relevance
“…The radiation exposure associated with the individual EVT (median DAP 4069 cGycm 2 ) appears to be moderate overall. This is consistent with recently published results from a working group from Essen that described EVT (with nimodipine) compared to other therapeutic interventions such as thrombectomy or aneurysm coiling as having a substantially lower radiation exposure [21].…”
Section: Discussionsupporting
confidence: 91%
See 1 more Smart Citation
“…The radiation exposure associated with the individual EVT (median DAP 4069 cGycm 2 ) appears to be moderate overall. This is consistent with recently published results from a working group from Essen that described EVT (with nimodipine) compared to other therapeutic interventions such as thrombectomy or aneurysm coiling as having a substantially lower radiation exposure [21].…”
Section: Discussionsupporting
confidence: 91%
“…Die mit der einzelnen EST verbundene Strahlenbelastung (DFP im Median 4069 cGycm²) erscheint insgesamt moderat. Dies passt zu jüngst veröffentlichten Ergebnissen einer Essener Arbeitsgruppe, welche EST (mit Nimodipin) im Vergleich mit anderen therapeutischen Interventionen wie Thrombektomie oder Aneurysmacoiling als mit substanziell geringerer Strahlenbelastung beschrieben hat [21]. Insgesamt zeigten die Auswertungen der Registerdaten sehr wenige Komplikationen im Rahmen der EST (1,2 %, überwiegend akute Thromboembolien und Dissektionen).…”
Section: Diskussionunclassified