2022
DOI: 10.1016/j.jenvrad.2022.106830
|View full text |Cite
|
Sign up to set email alerts
|

Radiation exposure due to 222Rn, 220Rn and their progenies in three metropolises in China and Japan with different air quality levels

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(9 citation statements)
references
References 33 publications
0
7
0
Order By: Relevance
“…In an intercomparison experiment carried out in a test chamber, the following average AMD values and regions (nm) were found for the unattached RnP [100]: 0.66 (0.53-0.86) for 218 Po, 0.80 (0.53-1.76) for 214 Pb, and 0.91 (0.53-2.20) for 214 Bi. The following were found for TnP: 0.73 (0.53-0.97) for 212 Pb and 0.85 (0.53-2.31) for 212 Bi. According to Huet et al [101], diameters (nm) of the unattached 218 Po, 214 Pb, and 214 Bi in an aged aerosol were similar and close to 0.85×/:1.25, and of the attached RnP, to 190×/:1.64.…”
Section: Radon Short-lived Products As Radioactive Aerosolsmentioning
confidence: 77%
See 4 more Smart Citations
“…In an intercomparison experiment carried out in a test chamber, the following average AMD values and regions (nm) were found for the unattached RnP [100]: 0.66 (0.53-0.86) for 218 Po, 0.80 (0.53-1.76) for 214 Pb, and 0.91 (0.53-2.20) for 214 Bi. The following were found for TnP: 0.73 (0.53-0.97) for 212 Pb and 0.85 (0.53-2.31) for 212 Bi. According to Huet et al [101], diameters (nm) of the unattached 218 Po, 214 Pb, and 214 Bi in an aged aerosol were similar and close to 0.85×/:1.25, and of the attached RnP, to 190×/:1.64.…”
Section: Radon Short-lived Products As Radioactive Aerosolsmentioning
confidence: 77%
“…In a radon chamber containing carrier aerosol, the AMD values of 0.82, 0.79, 1.70, and 0.82 nm were obtained for the unattached 218 Po, 214 Pb, 214 Bi, and 214 Po, respectively [102]. For unattached 212 Pb, the diameter size range of 0.8-2.0 nm and AMTD of 1.32 nm have been reported, and for its attached form, the size range of 230-400 nm and AMTD of 352 nm [103]. An AMTD of 1.28 nm for unattached 218 Po was in the range of 1.04-1.55 nm, and that for unattached 214 Pb of 1.30 nm was in the range of 1.10-1.60 nm, while the AMAD for attached 214 Pb was 353 nm in the range of 240-550 nm and that for attached 214 Bi was 380 in the range of 250-540 nm [104].…”
Section: Radon Short-lived Products As Radioactive Aerosolsmentioning
confidence: 99%
See 3 more Smart Citations