Radiation Effects on Long Period Fiber Gratings: A Review

Abstract: Over the last years, fiber optic sensors have been increasingly applied for applications in environments with a high level of radiation as an alternative to electrical sensors, due to their: high immunity, high multiplexing and long-distance monitoring capability. In order to assess the feasibility of their use, investigations on optical materials and fiber optic sensors have been focusing on their response depending on radiation type, absorbed dose, dose rate, temperature and so on. In this context, this pape… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

3
13
1

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 38 publications
(17 citation statements)
references
References 93 publications
3
13
1
Order By: Relevance
“…The results are reported in Figure 6, and the industrial SVST Co-60 irradiator (Figure 6a) is compared to the currently proposed setup based on the customized GC-5000 ( Figure 6b). As can be observed, in both cases the LPG resonance wavelength associated to the 3rd order cladding mode shifted to higher wavelengths as a consequence of an increase in the core refractive index due to the radiation, which is in agreement with the literature [23]. The shift was equal to 3.7 nm after a total dose of 35 kGy in the case of the SVST Co-60 irradiator, whereas for the GC-5000 setup it was 4.7 nm after a total dose of 52.6 kGy.…”
Section: Resultssupporting
confidence: 92%
See 3 more Smart Citations
“…The results are reported in Figure 6, and the industrial SVST Co-60 irradiator (Figure 6a) is compared to the currently proposed setup based on the customized GC-5000 ( Figure 6b). As can be observed, in both cases the LPG resonance wavelength associated to the 3rd order cladding mode shifted to higher wavelengths as a consequence of an increase in the core refractive index due to the radiation, which is in agreement with the literature [23]. The shift was equal to 3.7 nm after a total dose of 35 kGy in the case of the SVST Co-60 irradiator, whereas for the GC-5000 setup it was 4.7 nm after a total dose of 52.6 kGy.…”
Section: Resultssupporting
confidence: 92%
“…The test was performed at a dose rate of 0.18 kGy/h up to a total dose of 35 kGy, at around 23 • C temperature, and it lasted around 300 h, as seen in the irradiation profile (i.e., dose versus time) reported in Figure 7b. The grating attenuation band shifted to higher wavelengths, in agreement with the literature [23]: the response showed an approximate linear trend at lower doses, subsequently the slope decreased until it reached a saturation level at about 15 kGy. Several breaks in the irradiation can be observed in Figure 7b, which resulted in a partial recovery of the wavelength shift in Figure 7a due to bleaching mechanisms [32], as the source had to be periodically retracted in the water tank.…”
Section: Resultssupporting
confidence: 91%
See 2 more Smart Citations
“…This study is focused on sensors based on gratings written in fiber optics. In recent years, this type of sensors have been studied in applications with ionizing radiation, characterizing how radiation affects their properties and its possible application in radiation dosimetry [8]. It is well known from previous studies that the effects of radiation induce changes in fiber gratings.…”
Section: Introductionmentioning