Radiation doses with various body weights of phantoms in brain 128-slice MDCT examination

Abstract: The effective dose (HE) and organ or tissue equivalent dose (HT) for use in brain computed tomography (CT) examinations with various body weights were evaluated. Thermoluminescent dosimeters (TLD-100H) were inserted into Rando and five anthropomorphic phantoms. These phantoms were made of polymethylmethacrylate (PMMA), according to the specifications of ICRU 48, with masses from 10 to 90 kg. Brain CT examinations were conducted, scanning the maxillae from the external auditory meatus to the parietal bone using… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
12
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 11 publications
(12 citation statements)
references
References 26 publications
0
12
0
Order By: Relevance
“…The Rando was embedded in the anthropomorphic material. The densities (g cm −3 ) of the components were 0.32 for the lungs, 0.98 for the soft tissue, and 2.70 for the skeleton [3,4,6,10].…”
Section: Volumetric Modulated Arc Therapy (Vmat) Via An Axesse Linear Accelerator (Linac)mentioning
confidence: 99%
See 3 more Smart Citations
“…The Rando was embedded in the anthropomorphic material. The densities (g cm −3 ) of the components were 0.32 for the lungs, 0.98 for the soft tissue, and 2.70 for the skeleton [3,4,6,10].…”
Section: Volumetric Modulated Arc Therapy (Vmat) Via An Axesse Linear Accelerator (Linac)mentioning
confidence: 99%
“…The volumetric modulated arc therapy (VMAT) of an Axesse (Elekta 2538) linear accelerator (linac) is a novel effective treatment for many cancers [2,3]. However, the Axesse generates high-energy up to 6 MV radiations during NPC treatment [4][5][6][7][8]. Patients may be exposed to undesirable high energy x-ray primarily due to out-of-field radiations.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…The contrast results from the difference of these materials’ linear attenuation coefficients and can be calculated, if the chemical composition and the physical density of the materials are known. Polymethyl methacrylate (PMMA) is a uniform material frequently used for phantom bodies 7,8 . A second material to generate a signal can be a homogeneous fructose solution, which has the advantage that the contrast can be adjusted by the concentration of the solution.…”
Section: Introductionmentioning
confidence: 99%