2009
DOI: 10.2214/ajr.08.1758
|View full text |Cite
|
Sign up to set email alerts
|

Radiation Dose in a “Triple Rule-Out” Coronary CT Angiography Protocol of Emergency Department Patients Using 64-MDCT: The Impact of ECG-Based Tube Current Modulation on Age, Sex, and Body Mass Index

Abstract: The overall effective radiation dose for triple rule-out coronary CTA was reduced by more than 50% with ECG-based tube current modulation without loss of image quality. Tube current modulation should be used for triple rule-out coronary CTA examinations whenever possible.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
30
0
3

Year Published

2009
2009
2017
2017

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 83 publications
(33 citation statements)
references
References 31 publications
0
30
0
3
Order By: Relevance
“…[20][21][22] These results also extend previously described radiation dose observed in clinical coronary CTA practice, the effectiveness of dose reduction techniques, and preserved image quality. 14,16,[23][24][25] Most importantly, these results demonstrate the sustained effect of this intervention >3 years across a variety of centers providing real world clinical coronary CTA services.…”
Section: Discussionmentioning
confidence: 69%
“…[20][21][22] These results also extend previously described radiation dose observed in clinical coronary CTA practice, the effectiveness of dose reduction techniques, and preserved image quality. 14,16,[23][24][25] Most importantly, these results demonstrate the sustained effect of this intervention >3 years across a variety of centers providing real world clinical coronary CTA services.…”
Section: Discussionmentioning
confidence: 69%
“…Many studies emphasized that the high-dose radiation exposure is due to long scanning length. [31][32][33][34] A meta-analysis published in 2013 highlighted the radiation aspect of the TRO-CT. Ayaram et al (2013) studied radiation exposure in 2,307 patients, of which 377 were included in the triple-rule-out CT group and 1,930 in the control group. A statistically significant difference was observed between the two groups, patients assessed with TRO-CT being exposed to a significantly higher dose of ionising radiation.…”
Section: Which Are the Eligible Patients For The Triple-rule-out Ct Pmentioning
confidence: 99%
“…Hierbei fließt der maximale Röhren-strom nur in den in aller Regel verwendeten diastolischen Anteilen der Herzphase, während in den systolischen Anteilen der Röhrenstrom deutlich reduziert wird. Für ein TRO-Protokoll konnte allein durch die Verwendung der Röhrenstrom-modulation die Strahlendosis um mehr als 50% reduziert werden [28]. Beim prospektiven "EKG-Gating" findet der Spiral-Scan nur während der Diastole statt.…”
Section: Prinzipunclassified
“…Beim prospektiven "EKG-Gating" findet der Spiral-Scan nur während der Diastole statt. Für das prospektive Gating konnten ähn-liche Dosiseinsparungen wie für die Nutzung der Röhrenstrommodulation gezeigt werden, die damit deutlich unter 10 mSv liegen [24,28].…”
Section: Prinzipunclassified