1992
DOI: 10.2172/10130387
|View full text |Cite
|
Sign up to set email alerts
|

Radiation damage of tile/fiber scintillator modules for the SDC calorimeter

L Hu1,
et al.
Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
5
0

Year Published

1993
1993
2013
2013

Publication Types

Select...
3
1

Relationship

2
2

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 1 publication
0
5
0
Order By: Relevance
“…The relationship of dose to "damage" (loss of light output) was assumed to be linear. The assumption of linearity has been checked experimentally [5]. Therefore, the assumed depth (z) distribution of the response of a radiation damaged EM calorimeter can be written; 1-d(z) = I -a E(z) (1) where dis the fractional light loss (damage), E(z) is the energy profile of 10 GeV electrons, and a is a normalization factor.…”
Section: Damage Profilementioning
confidence: 99%
“…The relationship of dose to "damage" (loss of light output) was assumed to be linear. The assumption of linearity has been checked experimentally [5]. Therefore, the assumed depth (z) distribution of the response of a radiation damaged EM calorimeter can be written; 1-d(z) = I -a E(z) (1) where dis the fractional light loss (damage), E(z) is the energy profile of 10 GeV electrons, and a is a normalization factor.…”
Section: Damage Profilementioning
confidence: 99%
“…The relationship of dose to "damage" (loss of light output) was assumed to be linear. The assumption of linearity has been checked experimentally [5]. Therefore, the assumed depth (z) distribution of the response of a radiation damaged EM calorimeter can be written;…”
Section: Damage Profilementioning
confidence: 99%
“…Energy for 170 GeV electrons incident on the HF as a function of the ratio of energxes in the front compartment, El, to the rear compartment, E2 with dmax = 0.5. a. compartment l is 10 plates, -- 5. Xo deep i b. compartment is 15 plates,--7.5 Xo deep c. compartment I is 20 plates, 10 Xo deep d. compartment 1 is 25 plates, 12........................ i.................. r-l ?o _............... ......................................... 4 C_ • ", ........................ l:::l !...\ ....................... : ........................... _...................... • o 1.5 .......... .... ..............El/E2 boundary, 1/81'Pb platesFig.…”
mentioning
confidence: 99%
“…Measured data with 3HF tiles and 02 fibers were compared with the previous measurements using SCSN81 tiles and BCF91A fibers [1,2]. The relative outputs at the maximum damaged tile after 6 Mrad of irradiation are listed in Table 1 for Modules #5, 8, 9 and 10.…”
Section: ) Comparison With Previous Measurementsmentioning
confidence: 99%
“…annealed, representing permanent damage to the tile/fiber system) and D > 6 Mrad (before complete annealing). The results are summarized in Table 3 along with the data from our previous measurements [1,2].…”
Section: ) Comparison With Previous Measurementsmentioning
confidence: 99%