Abstract: Improved diagnostic sensitivity of bronchsocopy for the investigation of peripheral pulmonary lesions (PPLs) with the use of radial probe endobroncial ultrasound (EBUS) has been reported, although diagnostic performance varies considerably.A systematic review of published literature evaluating radial probe EBUS accuracy was performed to determine point sensitivity and specificity, and to construct a summary receiveroperating characteristic curve. Sub-group analysis and linear regression was used to identify po… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

19
322
6
17

Year Published

2012
2012
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 369 publications
(364 citation statements)
references
References 59 publications
19
322
6
17
Order By: Relevance
“…Sensitivity and specificity of EBUS-TBLB for evaluation of PPL was based on our own experience and a published meta-analysis [10,17], while data for CT-PNB was based on our reported experience and published guidelines [2,10]. …”
Section: Other Input Parametersmentioning
confidence: 99%
See 1 more Smart Citation
“…Sensitivity and specificity of EBUS-TBLB for evaluation of PPL was based on our own experience and a published meta-analysis [10,17], while data for CT-PNB was based on our reported experience and published guidelines [2,10]. …”
Section: Other Input Parametersmentioning
confidence: 99%
“…We recognised that model input values may vary significantly across different institutions. For example, diagnostic sensitivity of EBUS-TBLB differs considerably between institutions [17], and there is significant discrepancy in reported complication rates following CT-PNB [2]. Therefore, a series of one-way sensitivity analyses were undertaken within the range of each parameter recorded in table 3, based on data from recent pooled analyses.…”
Section: Sensitivity Analysismentioning
confidence: 99%
“…It comprises combined use of large channel bronchoscope, ultrasound probe, and driving unit all connected to the ultrasonographic center. One of the latest meta-analyses of rEBUS included 16 trials with 1420 patients [11]. rEBUS had point specificity 100% and point sensitivity 73% for the detection of lung cancer.…”
Section: Radial and Linear Endobronchial Ultrasound (Ebus)mentioning
confidence: 99%
“…EBUS RP offers guidance during bronchoscopy to help reach the lesion. The diagnostic yield varied from 46% to 86.2% and pooled sensitivity was 73% for all lesions and even better in the diagnosis of lung cancer (15,16). There is no direct comparison between EBUS RB and fluoroscopy in lung cancer diagnosis (17), but combined these two modality increased the diagnostic yield (18).…”
Section: Endobroncial Ultrasound Radial Probe (Ebus Rp)mentioning
confidence: 99%
“…The most frequent complications of EBUS RP guidance biopsy are bleeding and pneumothorax. But these complications are self-limited and seldom required intervention (15,35).…”
Section: Endobroncial Ultrasound Radial Probe (Ebus Rp)mentioning