2022
DOI: 10.1007/s10877-022-00927-w
|View full text |Cite
|
Sign up to set email alerts
|

Racial effects on Masimo pulse oximetry: a laboratory study

Abstract: Recent publications have suggested that pulse oximeters exhibit reduced accuracy in dark-skinned patients during periods of hypoxemia. Masimo SET® (Signal Extraction Technology®) has been designed, calibrated, and validated using nearly equal numbers of dark and light skinned subjects, with the goal of eliminating differences between pulse oximetry saturation (SpO2) and arterial oxygen saturation (SaO2) values due to skin pigmentation. The accuracy concerns reported in dark-skinned patients led us to perform a… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
15
1

Year Published

2023
2023
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 22 publications
(19 citation statements)
references
References 17 publications
0
15
1
Order By: Relevance
“…According to regulations, 15% of the participant pool should be darkly pigmented. This requirement was met in (Wong et al 2021, Baker andWilson 2022) (White pool = 65.5%, Black pool 29.6%, White pool = 55.44%, Black pool = 44.56%), but not in other studies (Guber et al 2019, Michael et al 2020, Valbuena et al 2021, Wiles et al 2021, Bangash et al 2022, Wiles et al 2022. Despite this, the inaccuracies seen in Black or darkly skinned subjects mentioned above did not change, although it was difficult to make conclusive statements in studies with a small number of volunteers (Gabrielczyk and Buist 1988).…”
Section: Methodologiesmentioning
confidence: 99%
“…According to regulations, 15% of the participant pool should be darkly pigmented. This requirement was met in (Wong et al 2021, Baker andWilson 2022) (White pool = 65.5%, Black pool 29.6%, White pool = 55.44%, Black pool = 44.56%), but not in other studies (Guber et al 2019, Michael et al 2020, Valbuena et al 2021, Wiles et al 2021, Bangash et al 2022, Wiles et al 2022. Despite this, the inaccuracies seen in Black or darkly skinned subjects mentioned above did not change, although it was difficult to make conclusive statements in studies with a small number of volunteers (Gabrielczyk and Buist 1988).…”
Section: Methodologiesmentioning
confidence: 99%
“…A few specific points merit highlighting:(1) A systematic overestimation of SpO 2 in hypoxic patients of black skin pigmentation occurs with many SpO 2 monitors 60,61 (although at least one device has been demonstrated to be accurate regardless of skin tone). 62 (2) Haemolysis, which inevitably occurs on ECMO, can generate endogenous carbon monoxide release leading to carboxyhaemoglobinaemia. Indeed, it has been demonstrated that SpO 2 may become less accurate over time during prolonged ECMO runs due to a high prevalence of mild (>3%) carboxyhaemoglobinaemia which should be measured on serial blood gases.…”
Section: Monitoring Native Lung Function During Vv Ecmomentioning
confidence: 99%
“…(1) A systematic overestimation of SpO 2 in hypoxic patients of black skin pigmentation occurs with many SpO 2 monitors 60,61 (although at least one device has been demonstrated to be accurate regardless of skin tone). 62…”
Section: Monitoring Native Lung Function During Vv Ecmomentioning
confidence: 99%
“…The studies rarely mentioned or assessed other well-known sources of Sp o 2 measurement error and artifact that must be managed to obtain accurate Sp o 2 readings, including ambient light, motion, conditions causing venous pulsations in the tissue bed, electromagnetic interference, poor peripheral perfusion, sensor placement and application to the skin, optical shunting, colored dyes, nail polish, and other hemoglobins (carboxyhemoglobin and methemoglobin). The degree of success in managing many of these issues is device dependent and varies between manufacturers, despite compliance with regulatory standards, as was demonstrated in a recent follow-up investigation 4 . However, one might expect that many of the factors described previously appear as random effects in analysis, with limited effect on results.…”
mentioning