The Laboratory Rabbit, Guinea Pig, Hamster, and Other Rodents 2012
DOI: 10.1016/b978-0-12-380920-9.00009-2
|View full text |Cite
|
Sign up to set email alerts
|

Rabbit Colony Management and Related Health Concerns

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
9
0
2

Year Published

2017
2017
2023
2023

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(12 citation statements)
references
References 69 publications
1
9
0
2
Order By: Relevance
“…In all animals, in vivo imaging of anatomy and placental pyruvate metabolism was performed with hyperpolarized MRI, as pyruvate, lactate, alanine and bicarbonate are fundamental intermediates in the metabolism of glucose (figure 3a) [38]. MRI was performed with a 3T system (GE Healthcare, Waukesha, WI, USA) equipped with a 1 H 8-channel cardiac array coil for anatomical (T2-weighted) scans and a 13 C Helmholtz loop coil (ø = 20 cm) for metabolic maps of endogenous substrates using hyperpolarized MRI. Hyperpolarized MRI is a method for assessing metabolic processes in tissues in real time.…”
Section: Hyperpolarized Mrimentioning
confidence: 99%
See 4 more Smart Citations
“…In all animals, in vivo imaging of anatomy and placental pyruvate metabolism was performed with hyperpolarized MRI, as pyruvate, lactate, alanine and bicarbonate are fundamental intermediates in the metabolism of glucose (figure 3a) [38]. MRI was performed with a 3T system (GE Healthcare, Waukesha, WI, USA) equipped with a 1 H 8-channel cardiac array coil for anatomical (T2-weighted) scans and a 13 C Helmholtz loop coil (ø = 20 cm) for metabolic maps of endogenous substrates using hyperpolarized MRI. Hyperpolarized MRI is a method for assessing metabolic processes in tissues in real time.…”
Section: Hyperpolarized Mrimentioning
confidence: 99%
“…Hyperpolarized MRI is a method for assessing metabolic processes in tissues in real time. In vivo imaging of the chinchilla placenta was performed with standard 1 H-MRI, allowing visualization of the fetus and placenta, and hyperpolarized 13 C-MRI for assessment of pyruvate metabolism (figure 3a) [39]. Two millilitres of 90 mM [1-13 C]-pyruvate were injected into the tail vein catheter over a period of 15 s. A slice-selective 13 TR/TE/ TE = 100 ms/0.9 ms/0.9 ms, FOV = 120 × 120 mm 2 , 5 × 5 mm 2 real resolution and an axial slice thickness of 20 mm covering the placenta and a part of the fetus.…”
Section: Hyperpolarized Mrimentioning
confidence: 99%
See 3 more Smart Citations