1998
DOI: 10.3109/17453679809002350
|View full text |Cite
|
Sign up to set email alerts
|

RAB-plate vs Richards CHS plate for unstable trochanteric hip fractures: A randomized study of 233 patients with 1 -year follow-up

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

3
15
0

Year Published

1999
1999
2022
2022

Publication Types

Select...
7
2

Relationship

1
8

Authors

Journals

citations
Cited by 34 publications
(18 citation statements)
references
References 22 publications
3
15
0
Order By: Relevance
“…The results with the SGN compare favourably with those of previous reports on the SHS 3,4,[7][8][9]31 and are comparable with those previously reported with the MSP. 4,9-11 The main problem remains the risk of intra-operative fractures, 3/109 (2.75%) in our study, although, in most cases, they were induced by inappropriate surgical technique.…”
Section: Discussionsupporting
confidence: 90%
See 1 more Smart Citation
“…The results with the SGN compare favourably with those of previous reports on the SHS 3,4,[7][8][9]31 and are comparable with those previously reported with the MSP. 4,9-11 The main problem remains the risk of intra-operative fractures, 3/109 (2.75%) in our study, although, in most cases, they were induced by inappropriate surgical technique.…”
Section: Discussionsupporting
confidence: 90%
“…3,4 In the case of unstable trochanteric fractures (J-M type 3 to 5) 1 and subtrochanteric fractures, 5 the treatment is more controversial and the rate of failure for the SHS in these fractures is considerably higher, ranging from 4% to 15%. 3,4,[6][7][8][9] The Medoff sliding plate (MSP) evolved from the SHS and gives axial compression along both the femoral neck (optional) and the femoral shaft. It has produced remarkably good results in prospective trials in both unstable trochanteric and subtrochanteric fractures with a rate of failure of 2% to 4%.…”
mentioning
confidence: 99%
“…Parker (1996) found that femoral medialization was closely associated with fixation failure, and failures increased 7-fold, if medialization of more than 1/3 of the femoral diameter at the fracture site occurred. Although the DHS is the most widely used implant, the average fixation failure rate is about 10% in unstable intertrochanteric fractures (Bannister et al 1990, Bridle et al 1991, Leung et al 1992, Desjardins et al 1993, Buciuto et al 1998, Watson et al 1998). Addition of a trochanteric stabilizing plate to the DHS aims to prevent or reduce excessive femoral medializa-tion (Madsen et al 1998), but it may impede the function of the lag screw thus preventing bone-tobone contact at fracture impaction.…”
mentioning
confidence: 99%
“…In our study, only 2 failures of fixation (1.3%) occurred. In previous studies on trochanteric fractures treated with the SHS, the rate of fixation failure has varied between 0% and 26% (Sernbo et al 1988, Davis et al 1990, Nungu et al 1991, Barrios et al 1993, Desjardins et al 1993, Radford et al 1993, Stappaerts et al 1995, Leung et al 1996, Buciuto et al 1998, Watson et al 1998, Lunsjö et al 2001b). The most common mode of fixation failure has been a cut-out of the lag screw through the femoral head.…”
Section: Discussionmentioning
confidence: 99%