2011
DOI: 10.3938/jkps.59.3619
|View full text |Cite
|
Sign up to set email alerts
|

R&D Status of High-current Accelerators at IFP

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2013
2013
2018
2018

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(8 citation statements)
references
References 0 publications
0
8
0
Order By: Relevance
“…The stability and the reliability of the pulsed power system strongly depend on the performance of the switches used in the system. Different types and parameters of switches have been studied and designed for different purposes [1]- [5]. The typical switch applied for the Marx generators is the coaxial spark gap gas switch with working voltage of 200 kV and jitter of 2 ns [2].…”
Section: A High-power Switches With Low Jittermentioning
confidence: 99%
See 1 more Smart Citation
“…The stability and the reliability of the pulsed power system strongly depend on the performance of the switches used in the system. Different types and parameters of switches have been studied and designed for different purposes [1]- [5]. The typical switch applied for the Marx generators is the coaxial spark gap gas switch with working voltage of 200 kV and jitter of 2 ns [2].…”
Section: A High-power Switches With Low Jittermentioning
confidence: 99%
“…The typical switch applied for the Marx generators is the coaxial spark gap gas switch with working voltage of 200 kV and jitter of 2 ns [2]. The cylindrical gas switch working at voltage of 300-400 kV with time jitter of less than 1 ns was designed for the LIA [1]. Selfbreakdown water switch with working voltage of 3 MV at current of 500 kA was developed for Z -pinch driver [4].…”
Section: A High-power Switches With Low Jittermentioning
confidence: 99%
“…The Institute for Fluid Physics in China is home to three LIAs for flash radiography: LIAXF, Dragon-I and Dragon-II [99][100][101][102][103][104][105]. LIAXF and Dragon-I are single pulse accelerators, but Dragon-II has three pulses.…”
Section: Accelerators At the Ifpmentioning
confidence: 99%
“…Second, there must be a discontinuity within the accelerator walls such as accelerating gaps. This latter point makes the instability especially concerning for users of linear induction accelerators (LIAs) [4][5][6] and for present designers of new LIAs such as the Los Alamos National Laboratory, the Institute of Fluid Physics (China Academy of Engineering Physics) [7], and the Budker Institute of Nuclear Physics (Russian Academy of Sciences) [8].…”
Section: Introductionmentioning
confidence: 99%