2020
DOI: 10.1016/j.ejpb.2020.05.002
|View full text |Cite
|
Sign up to set email alerts
|

Quicker, deeper and stronger imaging: A review of tumor-targeted, near-infrared fluorescent dyes for fluorescence guided surgery in the preclinical and clinical stages

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
23
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 49 publications
(25 citation statements)
references
References 158 publications
0
23
0
Order By: Relevance
“…Apart from the extra costs and logistic planning, this leads to an extra burden for pediatric OS, ES, and RMS patients. Therefore, smaller targeting moiety alternatives such as antibody fragments, peptide conjugates and small molecule conjugates may be advantageous for FGS [33]. Briefly, tracers smaller than 60 kDa are generally cleared via the kidneys instead of via the liver, resulting in faster blood clearance from non-targeted tissues.…”
Section: Disadvantages Of Using Antibodies For Fluorescence-guided Surgery and Their Alternativesmentioning
confidence: 99%
See 2 more Smart Citations
“…Apart from the extra costs and logistic planning, this leads to an extra burden for pediatric OS, ES, and RMS patients. Therefore, smaller targeting moiety alternatives such as antibody fragments, peptide conjugates and small molecule conjugates may be advantageous for FGS [33]. Briefly, tracers smaller than 60 kDa are generally cleared via the kidneys instead of via the liver, resulting in faster blood clearance from non-targeted tissues.…”
Section: Disadvantages Of Using Antibodies For Fluorescence-guided Surgery and Their Alternativesmentioning
confidence: 99%
“…Briefly, tracers smaller than 60 kDa are generally cleared via the kidneys instead of via the liver, resulting in faster blood clearance from non-targeted tissues. Consequently, a high tumor-to-background contrast can be attained within hours after the administration of a tumor-specific smaller targeting moiety alternative-based tracer [26,33,125].…”
Section: Disadvantages Of Using Antibodies For Fluorescence-guided Surgery and Their Alternativesmentioning
confidence: 99%
See 1 more Smart Citation
“…Fluorescent chemosensors have already shown great promise in real-world situations and applications, including but not limited to: the detection of environmental waste pollutants, detection of chemical warfare agents, fluorescence guided surgery, whole body diagnostic imaging, in vivo flow cytometry, and eHealth diagnostic devices (point of care (POC) testing) (Christodouleas et al, 2018;Jiao et al, 2020;Wei and Xunbin, 2021). In addition, colorimetric sensors have been established as potentially attractive sensing platforms due to their low cost as well as their capability to respond to stimuli with concurrent colour (UV-Vis) changes that could be discerned using the naked eye (LĂłpez-Alled et al, 2017;Gwynne et al, 2021a;Gwynne et al, 2021b).…”
Section: Introductionmentioning
confidence: 99%
“…These biomarkers form the basis for tumor-targeted nuclear and fluorescence imaging in various malignancies, including PDAC [ 34 , 42 , 43 , 44 ]. Molecular imaging of oncological targets has been of particular interest in the past decade: multiple (pre)clinical trials have shown promising results for PDAC-targeted PET/CT and NIR-imaging, for diagnostic as well as therapeutic purposes [ 45 , 46 , 47 , 48 ].…”
Section: Introductionmentioning
confidence: 99%