2021
DOI: 10.1088/1748-0221/16/07/p07034
|View full text |Cite
|
Sign up to set email alerts
|

Quenching factor measurements of sodium nuclear recoils in NaI:Tl determined by spectrum fitting

Abstract: We have performed measurements of sodium nuclear recoils in NaI:Tl crystals, following scattering by neutrons produced in a 7Li(p,n)7Be reaction. Understanding the light output from such recoils, which is reduced relative to electrons of equivalent energy by the quenching factor, is critical to interpret dark matter experiments that search for nuclear scattering interactions. We have developed a spectrum-fitting methodology to extract the quenching factor from our measurements, and report quenching factors for… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
3

Relationship

1
8

Authors

Journals

citations
Cited by 17 publications
(12 citation statements)
references
References 19 publications
0
12
0
Order By: Relevance
“…The total charge of the waveform is taken as the sum of these two components. For further details, including a schematic representation of this approach, see Ref [15].…”
Section: Data Processing and Event Selectionmentioning
confidence: 99%
“…The total charge of the waveform is taken as the sum of these two components. For further details, including a schematic representation of this approach, see Ref [15].…”
Section: Data Processing and Event Selectionmentioning
confidence: 99%
“…Independent experiments with the same target material NaI(Tl) as DAMA would go a long way to resolve the controversy, allowing a model-independent test of the annual modulation signal. However, the lack of a deep understanding and/or modelling of quenching factors for scintillation of nuclear recoils in NaI(Tl) introduces some systematics in this test for DM candidates releasing the energy through nuclear recoils [239][240][241][242][243][244]. Better measurements of quenching factors for crystals having different properties using the same analysis methods and set-ups would help [245].…”
Section: Puzzling Excesses In Dark Matter Searches and How To Resolve...mentioning
confidence: 99%
“…This is not the case for NaI(Tl) scintillators. Measurements of QF in the energy region relevant for DM searches, and in particular for the comparison with DAMA/LIBRA in case the signal is attributed to nuclear recoils, do not agree, and in fact are affected by strong discrepancies (QF dependent on the energy versus constant values, for instance) [59][60][61][62][63][64][65][66][67][68][69].…”
Section: The Neutron Calibration Programmentioning
confidence: 99%