2014
DOI: 10.1007/s00340-014-5808-z
|View full text |Cite
|
Sign up to set email alerts
|

Quantum-noise-limited cavity ring-down spectroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
15
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
6
1
1

Relationship

2
6

Authors

Journals

citations
Cited by 33 publications
(15 citation statements)
references
References 20 publications
0
15
0
Order By: Relevance
“…1(a). A continuous-wave (CW) external cavity diode laser (ECDL), tunable from 1570 nm to 1630 nm [27,28], was coupled to an erbium-doped fiber amplifier (EDFA, 180 mW optical power) prior to seeding the EOMs for comb generation and cavity-comb coupling. The probe and LO combs were created using phase modulators of nominally 20 GHz 3-dB RF bandwidth and were driven by separate steprecovery diodes used to imprint RF harmonics upon the CW optical carrier in each arm.…”
Section: Methodology Of Comb Generationmentioning
confidence: 99%
“…1(a). A continuous-wave (CW) external cavity diode laser (ECDL), tunable from 1570 nm to 1630 nm [27,28], was coupled to an erbium-doped fiber amplifier (EDFA, 180 mW optical power) prior to seeding the EOMs for comb generation and cavity-comb coupling. The probe and LO combs were created using phase modulators of nominally 20 GHz 3-dB RF bandwidth and were driven by separate steprecovery diodes used to imprint RF harmonics upon the CW optical carrier in each arm.…”
Section: Methodology Of Comb Generationmentioning
confidence: 99%
“…Spectra can then be recorded simply by stepping the EOM drive frequency in increments of the cavity's free spectral range. We have demonstrated scanning rates which are limited only by the cavity's response time and a noise-equivalent absorption coefficient (NEA) as low as 6 Â 10 À 14 cm À 1 Hz À 1/2 [5,11].…”
Section: Experimental Approachmentioning
confidence: 98%
“…This sample contained 425.4 (11) 3. The pressure measurements were made with a NIST-calibrated capacitance diaphragm gauge with a full-scale response of 133.3 kPa and a relative standard uncertainty less than 0.1%.…”
Section: Experimental Approachmentioning
confidence: 99%
“…As a result, very low noise photodetectors are required to achieve high signal-to-noise ratios on the ring-down decay events. In addition, high efficiency electro-optic modulators are not available in the mid-infrared, which can make Pound-Drever-Hall locking [11] far more challenging [12] as well as precluding the use of recently developed frequency-agile techniques [6, 7, 13]. …”
mentioning
confidence: 99%