2022
DOI: 10.1016/j.bios.2021.113810
|View full text |Cite
|
Sign up to set email alerts
|

Quantum dots assembly enhanced and dual-antigen sandwich structured lateral flow immunoassay of SARS-CoV-2 antibody with simultaneously high sensitivity and specificity

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
28
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 31 publications
(28 citation statements)
references
References 46 publications
0
28
0
Order By: Relevance
“…Jia et al assembled 3D QD assembly labels using dendritic silica and OA-capped CdSe/ CdS/ZnS QDs and used it for the detection of SARS-CoV-2. [170] The synthesized 3D QD assembly labels achieved 100% sensitivity and 100% specificity in over 300 negative and 97 positive samples, confirmed by polymerase chain reaction (PCR). Other QD-related SARS-CoV-2 assays also achieved excellent performance.…”
Section: Detection Of Virusmentioning
confidence: 84%
“…Jia et al assembled 3D QD assembly labels using dendritic silica and OA-capped CdSe/ CdS/ZnS QDs and used it for the detection of SARS-CoV-2. [170] The synthesized 3D QD assembly labels achieved 100% sensitivity and 100% specificity in over 300 negative and 97 positive samples, confirmed by polymerase chain reaction (PCR). Other QD-related SARS-CoV-2 assays also achieved excellent performance.…”
Section: Detection Of Virusmentioning
confidence: 84%
“…S2C and D , under the blocking effect of casein, the magnetic T/C and the fluorescent T/C of negative sample were decreased significantly. This might be because the non-specific interaction between the IMagDQD with the antibody on NC membrane could be effectively blocked by macromolecular protein [ 38 ]. Fig.…”
Section: Resultsmentioning
confidence: 99%
“…The gold-based lateral flow immunoassay (GLFIA) commonly applied in antibody/serological assays and risks exposing false-negative and false-positive interpretations is not suitable for large-scale population screening. Jia et al [ 23 ] constructed a novel fluorescent lateral flow immunoassay (LFIA), which, to overcome the problem of false negatives, using hydrophobic quantum dots to ensure single-labeled high-intensity fluorescence and to overcome the problem of false positives, a double antigen sandwich construction utilizing labeled/immobilized SARS-CoV-2 RBD. Analysis of nearly 400 clinical samples yielded 100% sensitivity and 100% specificity.…”
Section: Current Trends In Covid-19 Diagnostics: From Centralized Lab...mentioning
confidence: 99%