2003
DOI: 10.1023/a:1025496716711
|View full text |Cite
|
Sign up to set email alerts
|

Quantu-design and development of a software package dedicated to k0-standardized NAA

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
9
0
3

Year Published

2004
2004
2018
2018

Publication Types

Select...
8
2

Relationship

3
7

Authors

Journals

citations
Cited by 69 publications
(12 citation statements)
references
References 8 publications
0
9
0
3
Order By: Relevance
“…The irradiation was carried out in the IEA-R1 nuclear research reactor, IPEN/CNEN, São Paulo, Brazil, at a thermal neutron flux of 7 9 10 12 cm -2 s -1 during 4 h. Irradiated samples were returned to CENA/USP and the induced activity was measured at four occasions, with decay times of 4, 7, 15 and 30 days, and counting time of 15, 30, 60 and 120 min, respectively. Two different HPGe detectors were used, with relative efficiencies of 50 and 55 % for the photopeak 1332 keV of 60 Co. Mass fractions of chemical elements and the uncertainties were calculated by the k 0 -method [12], using the software package Quantu [13].…”
Section: Methodsmentioning
confidence: 99%
“…The irradiation was carried out in the IEA-R1 nuclear research reactor, IPEN/CNEN, São Paulo, Brazil, at a thermal neutron flux of 7 9 10 12 cm -2 s -1 during 4 h. Irradiated samples were returned to CENA/USP and the induced activity was measured at four occasions, with decay times of 4, 7, 15 and 30 days, and counting time of 15, 30, 60 and 120 min, respectively. Two different HPGe detectors were used, with relative efficiencies of 50 and 55 % for the photopeak 1332 keV of 60 Co. Mass fractions of chemical elements and the uncertainties were calculated by the k 0 -method [12], using the software package Quantu [13].…”
Section: Methodsmentioning
confidence: 99%
“…The induced radioactivity was measured in the Centro de Energia Nuclear na Agricultura at decay periods of about 4, 7, 15, and 40 days using two different germanium detectors with 50% and 55% relative efficiencies for the 1,332 keV photopeak from 60 Co. Results were calculated by the k 0 -method using the in-house software package Quantu [5].…”
Section: Methodsmentioning
confidence: 99%
“…Details of the analysis and the presented results can be found elsewhere (França et al, 2004b). The uncertainties were calculated by the Quantu software (Bacchi et al, 2003) and compared to the standard deviation observed (Fig. 1).…”
Section: Methodsmentioning
confidence: 99%