Quantitative phase analysis from X-ray diffraction in Y-TZP dental ceramics: A critical evaluation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
15
0
12

Year Published

2016
2016
2024
2024

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 53 publications
(30 citation statements)
references
References 27 publications
2
15
0
12
Order By: Relevance
“…The specimens sintered at 60 minutes also presented low densities 26 that evaluated another commercial pre-sintered Y-TZP. 30 According to the results of density presented by Arata et al (2014Arata et al ( , 2015 2,27 the Y-TZP density after conventional sintering presented similar values compared with the microwave sintering at 1450°C in this present study. However, the VM-1350 specimen showed an evident intergranular residual porosity and smaller grain size (Figure 3).…”
Section: Discussionsupporting
confidence: 71%
See 2 more Smart Citations
“…The specimens sintered at 60 minutes also presented low densities 26 that evaluated another commercial pre-sintered Y-TZP. 30 According to the results of density presented by Arata et al (2014Arata et al ( , 2015 2,27 the Y-TZP density after conventional sintering presented similar values compared with the microwave sintering at 1450°C in this present study. However, the VM-1350 specimen showed an evident intergranular residual porosity and smaller grain size (Figure 3).…”
Section: Discussionsupporting
confidence: 71%
“…For comparison purposes, one specimen of each ceramic was sintered in a conventional electrical box furnace (Lindberg/ Blue M, Asheville, NC, USA) at 1530°C for 2 hours. 2,27 The heating rates were at (a) microwave oven: 25°C/ min until 1000°C, 15°C/min until 1300°C, 5°C/min until 1450°C and (b) conventional furnace: 10°C/min until 800°C, 5°C/min until 1530°C and cooling at 25°C/min until room temperature.…”
Section: Sintering Protocolsmentioning
confidence: 99%
See 1 more Smart Citation
“…XRD spectra were collected from each sample over a 2 θ range between 15° and 70° with a step size of 0.05° and a count time of 4 s per step. Monoclinic phase content was quantified using the Garvie and Nicholson equation modified by Toraya …”
Section: Methodsmentioning
confidence: 99%
“…Monoclinic phase content was quantified using the Garvie and Nicholson equation modified by Toraya. 30 A profilometer (Surfcom 480A, Accretech, Tokyo, Japan) was used to measure surface roughness with a tracing length of 4.0 mm and a cut-off value of 0.8 mm. The arithmetic average roughness (R a ) and ten-point average roughness (R z ) of each material was calculated from a total of 15 points from all three specimens.…”
Section: Analyses Of Surface Characteristicsmentioning
confidence: 99%