Quantitative Measurement of Cerebrospinal Fluid Amyloid-β Species by Mass Spectrometry

Abstract: Background: High sensitivity liquid chromatography mass spectrometry (LC-MS/MS) was recently introduced to measure amyloid-β (Aβ) species, allowing for a simultaneous assay that is superior to ELISA, which requires more assay steps with multiple antibodies. Objective: We validated the Aβ1-38, Aβ1-40, Aβ1-42, and Aβ1-43 assay by LC-MS/MS and compared it with ELISA using cerebrospinal fluid (CSF) samples to investigate its feasibility for clinical application. Methods: CSF samples from 120 subjects [8 Alzheimer’… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
9
0
3

Year Published

2021
2021
2024
2024

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 18 publications
(14 citation statements)
references
References 45 publications
(70 reference statements)
1
9
0
3
Order By: Relevance
“…The Na + and K + concentrations were determined at 589 and 766.5 nm using an iCE 3300 AAS atomic absorption spectrometer (Thermo, USA). The endogenous ABA content before and after exposure to salt stress was determined with a 5,500 QTRAP(AB SCIEX) mass spectrometer using liquid chromatography–mass spectrometry as previously described (Chen et al, 2003; Seino et al, 2021).…”
Section: Methodsmentioning
confidence: 99%
“…The Na + and K + concentrations were determined at 589 and 766.5 nm using an iCE 3300 AAS atomic absorption spectrometer (Thermo, USA). The endogenous ABA content before and after exposure to salt stress was determined with a 5,500 QTRAP(AB SCIEX) mass spectrometer using liquid chromatography–mass spectrometry as previously described (Chen et al, 2003; Seino et al, 2021).…”
Section: Methodsmentioning
confidence: 99%
“…Sandwich ELISA was used to quantify plasma Aβ40 and Aβ42 levels using the Human/Rat ß Amyloid (40) ELISA Kit Wako II and Human/Rat ß Amyloid (42) ELISA Kit Wako High‐Sensitive (Wako Pure Chemical Industries, Ltd., Osaka, Japan). The antibodies used and assay sensitivities were previously described 15,20–22 . The 129 outliers of plasma Aβ40 or Aβ42 levels were excluded by the ROUT method ( Q = 1%) 23 …”
Section: Methodsmentioning
confidence: 99%
“…CSF total tau and phosphorylated-tau181 were analyzed by electrochemiluminescence immunoassay following a Roche Studying Protocol in UPenn/ADNI biomarker Laboratory ( Hansson et al, 2018 ), which were derived from UPENNBIOMK9_04_19_17.csv file. CSF Aβ42 and Aβ40 concentration were analyzed using 2D-UPLC tandem mass spectrometry, which was also widely used in measuring CSF biomarkers and its reproducibility and accuracy in measuring CSF Aβ42 and Aβ40 have also been confirmed ( Korecka et al, 2014 ; Weber et al, 2019 ; Seino et al, 2021 ). Then, Aβ42/Aβ40 ratio was calculated for each subject and a published cut-off point of ratio (<0.138) was applied to identify positive amyloid deposition.…”
Section: Methodsmentioning
confidence: 99%