2020
DOI: 10.3390/s20174827
|View full text |Cite
|
Sign up to set email alerts
|

Quantitative Long-Term Monitoring of the Circulating Gases in the KATRIN Experiment Using Raman Spectroscopy

Abstract: The Karlsruhe Tritium Neutrino (KATRIN) experiment aims at measuring the effective electron neutrino mass with a sensitivity of 0.2 eV/c2, i.e., improving on previous measurements by an order of magnitude. Neutrino mass data taking with KATRIN commenced in early 2019, and after only a few weeks of data recording, analysis of these data showed the success of KATRIN, improving on the known neutrino mass limit by a factor of about two. This success very much could be ascribed to the fact that most of the system c… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
24
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 18 publications
(29 citation statements)
references
References 45 publications
0
24
0
Order By: Relevance
“…In order to acquire the molar fractions of the "tertiary" samples, Equation ( 7) was used with the initial molar fractions and a fixed value for the equilibrium constant of k eq (T = 298 K) = 2.574 and k eq (T = 298 K) = 3.811 for HT and DT, respectively. The relative Raman signals for "binary" and "tertiary" sample composition, i.e., at the beginning of the mixing process and after equilibration, respectively, were derived using the model function given in Equation (7); the related exponential fit incorporated all data values over the full equilibration circulation period of~72 h, as illustrated in Figure 5 above.…”
Section: Measurement Results Obtained For Tritiated Isotopologue Mixturesmentioning
confidence: 99%
See 4 more Smart Citations
“…In order to acquire the molar fractions of the "tertiary" samples, Equation ( 7) was used with the initial molar fractions and a fixed value for the equilibrium constant of k eq (T = 298 K) = 2.574 and k eq (T = 298 K) = 3.811 for HT and DT, respectively. The relative Raman signals for "binary" and "tertiary" sample composition, i.e., at the beginning of the mixing process and after equilibration, respectively, were derived using the model function given in Equation (7); the related exponential fit incorporated all data values over the full equilibration circulation period of~72 h, as illustrated in Figure 5 above.…”
Section: Measurement Results Obtained For Tritiated Isotopologue Mixturesmentioning
confidence: 99%
“…An in-depth description of the spectrum processing can be found in references [7,55]; thus, only a brief summary of the major processing steps is given here. In general, prior to the extraction of the concentration data, the following procedures were applied to each individual LARA acquisition:…”
Section: Data Evaluationmentioning
confidence: 99%
See 3 more Smart Citations