2004
DOI: 10.1016/j.jchromb.2003.10.023
|View full text |Cite
|
Sign up to set email alerts
|

Quantitative liquid chromatographic determination of sanguinarine in cell culture medium and in rat urine and plasma

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
8
0

Year Published

2004
2004
2015
2015

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 15 publications
(10 citation statements)
references
References 17 publications
2
8
0
Order By: Relevance
“…The molecular ion SA [M + H + ] was measured at m/z 332 and specific products of fragmentation at m/z 317 and 274, the molecular ion DHSA [M + H + ] was measured at m/z 334 and specific products of fragmentation at m/z 318, 260 and 232, and the molecular ion BCA [M + H + ] was measured at m/z 230 and specific products of fragmentation at m/z 202. According to literature, the fragments were in good coincidence with so far published data [9][10][11].…”
Section: Procedures Optimizationsupporting
confidence: 80%
“…The molecular ion SA [M + H + ] was measured at m/z 332 and specific products of fragmentation at m/z 317 and 274, the molecular ion DHSA [M + H + ] was measured at m/z 334 and specific products of fragmentation at m/z 318, 260 and 232, and the molecular ion BCA [M + H + ] was measured at m/z 230 and specific products of fragmentation at m/z 202. According to literature, the fragments were in good coincidence with so far published data [9][10][11].…”
Section: Procedures Optimizationsupporting
confidence: 80%
“…5-1): precursor ion m/z 332.09 (M + , calc. for C 20 H 13 NO 4 ), product ion m/z 317.07 [M-CH 3 ] + , 304.10 [M-CO] + , 289.07 [M-CO-CH 3 ] + , 274.08 [M-CO-CH 2 O] + , 246.09 [M-2CO-CH 2 O] + , 216.08 [M-2CO-2CH 2 O] + were in good agreement with the literature [18]. So compound 1 was identified as sanguinarine.…”
Section: Resultssupporting
confidence: 87%
“…The recoveries of sanguinarine and chelerythrine were 40-60% in both water and urine because these two compounds are quaternary ammonium alkaloids and were tightly absorbed onto the SPE absorbent. However, in the blood samples, the recoveries were 5-11% for sanguinarine and chelerythrine, beside the reason above-mentioned, which can be interpreted that the presence of quaternary nitrogen atom led to the high binding capacity of sanguinarine and chelerythrine to cellular proteins and DNA in the blood [28][29][30][31]. As a result, sanguinarine and chelerythrine could not be detected in the blood samples with the proposed method.…”
Section: Sample Pretreatment Proceduresmentioning
confidence: 83%