2018
DOI: 10.1186/s12917-018-1384-5
|View full text |Cite
|
Sign up to set email alerts
|

Quantitative evaluation of canine urinary bladder transitional cell carcinoma using contrast-enhanced ultrasonography

Abstract: BackgroundIn veterinary medicine, contrast-enhanced ultrasonography allowed the accurate quantification of liver, splenic and kidney vascularization in healthy dogs and the differentiation between malignant and benign hepatic, renal, and splenic nodules in dogs and cats based on perfusion patterns. The utility of contrast-enhanced ultrasonography in other applications is still under study.The aim of this study was to develop diagnostic criteria by contrast-enhanced ultrasonography in 8 client-owned adult dogs … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

4
19
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 19 publications
(23 citation statements)
references
References 30 publications
4
19
0
Order By: Relevance
“…In the present case, the CEUS images showed a loss of planes between the lesion and the bladder wall layers, with disappearance of the hyper-enhanced submucosal layer and hypo-enhanced muscle layer due to the presence of the hyper-enhanced tumor tissue. The disruption of the bladder wall muscular layer by enhancing tumor tissue confirms the infiltrative feature of the tumor [14].…”
Section: Discussionsupporting
confidence: 54%
“…In the present case, the CEUS images showed a loss of planes between the lesion and the bladder wall layers, with disappearance of the hyper-enhanced submucosal layer and hypo-enhanced muscle layer due to the presence of the hyper-enhanced tumor tissue. The disruption of the bladder wall muscular layer by enhancing tumor tissue confirms the infiltrative feature of the tumor [14].…”
Section: Discussionsupporting
confidence: 54%
“…Contrast-enhanced ultrasonography (CEUS) is an imaging modality that could improve the diagnostic accuracy of standard US: the use of intravascular contrast medium (CM), like the second-generation ones, may improve the visualization of blood perfusion and microvascular architecture, allowing qualitative and quantitative vascular assessment of various organs in both physiological and pathological conditions in dogs and cats [ 14 , 15 , 16 , 17 , 18 , 19 , 20 , 21 , 22 , 23 , 24 , 25 , 26 , 27 , 28 , 29 , 30 ]. Furthermore, CEUS has proved to be an extremely safe and well-tolerated technique [ 31 ].…”
Section: Introductionmentioning
confidence: 99%
“…Furthermore, CEUS has proved to be an extremely safe and well-tolerated technique [ 31 ]. In veterinary medicine, several studies have described the usefulness of this modality in the characterization of inflammatory and neoplastic diseases [ 16 , 18 , 19 , 21 , 23 , 24 , 25 , 26 , 27 , 28 , 29 , 30 , 32 ]. However, regarding the stomach, only one study has been conducted to investigate the reliability of low-mechanical index imaging compered to Doppler flowmetry for the assessment of gastric mucosal blood flow in healthy dogs, demonstrating the feasibility of CEUS quantitative evaluation in this organ [ 33 ].…”
Section: Introductionmentioning
confidence: 99%
“…CEUS examination was performed, using a linear transducer (10-12-MHz) probe with contrast agent capability. The contrast agent, INN-sulphur hexa uoride (SonoVue ® , Bracco International, Milan, Italy), was prepared following the manufacturer's recommendations and was rapidly injected (0.05 mL/kg of body weight) via a three-way stopcock and 18-gauge catheter placed in a cephalic vein, in accordance with a methodology previously reported [28,29]. Each dog received two bolus injections of contrast agent, which were standardised and administered by the same investigator (SDP).…”
Section: General Materialsmentioning