2020
DOI: 10.1177/1550059420918756
|View full text |Cite
|
Sign up to set email alerts
|

Quantitative EEG Findings in Patients With Psychogenic Nonepileptic Seizures

Abstract: Objective. Psychogenic nonepileptic seizures (PNES), is one of the clinical manifestations of conversion disorder that epileptiform discharges do not accompany. Factors capable of increasing susceptibility to these seizures have not been adequately investigated yet. This study aims to investigate the quantitative electroencephalography (QEEG) findings for PNES by evaluating the resting EEG spectral power changes during the periods between seizures. Methods. Thirty-nine patients (29 females, 10 males) diagnosed… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
19
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 8 publications
(22 citation statements)
references
References 39 publications
(41 reference statements)
3
19
0
Order By: Relevance
“…Patients with PNES-but not those with epilepsy-showed a decrease in beta power (desynchronization) prior to the PNES (minimum beta power at 5-6 s prior to the PNES). Arikan et al (2020) use quantitative EEG (QEEG) and fast Fourier transformation to examine spectral power across all frequency bands in adults with PNES. They found increased power at the following bands and locations: C3-high beta (25-30 Hz), C3-gamma (30-80 Hz), C3-gamma-1 (31-40 Hz), C3gamma-2 (41-50 Hz), P3-gamma (30-80 Hz), P3 gamma-1 (31-40 Hz).…”
Section: Introductionmentioning
confidence: 99%
“…Patients with PNES-but not those with epilepsy-showed a decrease in beta power (desynchronization) prior to the PNES (minimum beta power at 5-6 s prior to the PNES). Arikan et al (2020) use quantitative EEG (QEEG) and fast Fourier transformation to examine spectral power across all frequency bands in adults with PNES. They found increased power at the following bands and locations: C3-high beta (25-30 Hz), C3-gamma (30-80 Hz), C3-gamma-1 (31-40 Hz), C3gamma-2 (41-50 Hz), P3-gamma (30-80 Hz), P3 gamma-1 (31-40 Hz).…”
Section: Introductionmentioning
confidence: 99%
“…In four studies (based on two fully independent study samples), a comparable number of males and females were examined. In two studies, the patient sample had higher prevalence of females [23,49]. All participants were not taking any medications in three studies [23,48,49], while in the sample shared by the remaining three studies most patients were taking AEDs, benzodiazepines or antidepressant medications [46,47,50].…”
Section: Studies In Pnes Cohortsmentioning
confidence: 97%
“…Effect sizes were calculated by means of standardized mean difference (Cohen's d; [21]). Cohen's d was calculated based on means and standard deviations or standard errors for all studies with available data, except for [22] and [23] for which the F-statistic and t-statistic values, respectively, were used, and [24] for which Mann-Whitney U-values were used. Statistical synthesis was to be performed if 5 or more studies that investigated the same resting-state EEG metric in people with the same diagnosis and a control group were individuated [25].…”
Section: Data Synthesis and Analysismentioning
confidence: 99%
See 2 more Smart Citations