2005
DOI: 10.1093/jaoac/88.6.1714
|View full text |Cite
|
Sign up to set email alerts
|

Quantitative Determination of Paralytic Shellfish Poisoning Toxins in Shellfish Using Prechromatographic Oxidation and Liquid Chromatography with Fluorescence Detection: Collaborative Study

Abstract: A collaborative study was conducted for the determination of paralytic shellfish poisoning (PSP) toxins in shellfish. The method used liquid chromatography with fluorescence detection after prechromatographic oxidation of the toxins with hydrogen peroxide and periodate. The PSP toxins studied were saxitoxin (STX), neosaxitoxin (NEO), gonyautoxins 2 and 3 (GTX2,3; together), gonyautoxins 1 and 4 (GTX1,4; together), decarbamoyl saxitoxin (dcSTX), B-1 (GTX5), C-1 and C-2 (C1,2; together), and C-3 and C-4 (C3,4; t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
96
0
1

Year Published

2009
2009
2024
2024

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 246 publications
(103 citation statements)
references
References 0 publications
0
96
0
1
Order By: Relevance
“…The PST content was measured in 300 individual oysters (n = 9 oysters per toxic treatment and n = 30 nontoxic control oysters), according to Lawrence et al (2005) and Harwood et al (2013). Briefly, homogenised (Omni Tissue Homogeniser, Omni International, USA) oyster tissue was vortexed with 3 mL of 1% acetic acid solution.…”
Section: Toxin Analysismentioning
confidence: 99%
“…The PST content was measured in 300 individual oysters (n = 9 oysters per toxic treatment and n = 30 nontoxic control oysters), according to Lawrence et al (2005) and Harwood et al (2013). Briefly, homogenised (Omni Tissue Homogeniser, Omni International, USA) oyster tissue was vortexed with 3 mL of 1% acetic acid solution.…”
Section: Toxin Analysismentioning
confidence: 99%
“…However, one peak was observed at 2.86 min in the sample oxidized with peroxide ( Figure 5b). The detected peak might represent dcGTX2 or dcGTX3 based on the peak detection sequence proposed by Lawrence et al (2005).…”
Section: Resultsmentioning
confidence: 99%
“…The sample was then subjected to a pre-purification step by solid phase extraction (SPE) on C18 cartridges (Supelco). Separation of the different PSPs potentially present was performed by SPE with a 3mL carboxylic acid cartridges (Supelco), according to Lawrence et al (2005).…”
Section: Cyanotoxin Extractionmentioning
confidence: 99%
See 1 more Smart Citation
“…The method was described by Lawrence and Menard (1991) and was evaluated in 2002 in an international collaborative study involving 18 laboratories (Lawrence et al, 2004(Lawrence et al, , 2005. It was successfully validated for the toxins GTX1 and GTX4 together, GTX2 and GTX3 together, C1 and C2 together, C3 and C4 together, NeoSTX, STX, dcSTX and GTX5.…”
Section: Aoac Official Methods 200506 (Precolumn Methods)mentioning