2013
DOI: 10.1016/j.talanta.2013.08.022
|View full text |Cite
|
Sign up to set email alerts
|

Quantitative determination of calcium, magnesium, and zinc in fingernails by laser-induced breakdown spectroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0
1

Year Published

2014
2014
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 25 publications
(7 citation statements)
references
References 15 publications
0
6
0
1
Order By: Relevance
“…This behavior may also explain the observation by Rusak et al. 31 that pressed keratin pellets were not an effective LIBS calibration standard for an LIBS fingernail assay using a 1064 nm laser. Pressed keratin pellets created from a uniform homogenous powder would have no such asymmetrical striations or vertical layering, yielding more reproducible results than ablation, but not effectively modeling the behavior of a true fingernail.…”
Section: Resultsmentioning
confidence: 91%
See 1 more Smart Citation
“…This behavior may also explain the observation by Rusak et al. 31 that pressed keratin pellets were not an effective LIBS calibration standard for an LIBS fingernail assay using a 1064 nm laser. Pressed keratin pellets created from a uniform homogenous powder would have no such asymmetrical striations or vertical layering, yielding more reproducible results than ablation, but not effectively modeling the behavior of a true fingernail.…”
Section: Resultsmentioning
confidence: 91%
“…Rusak et al. 31 utilized LIBS with a 1064 nm laser to study Mg, Ca, and Zn in human fingernails obtained from 11 volunteers. Utilizing the Zn I line at 481 nm, a calibration graph with an R 2 value of 0.9896 was created after the determination of the absolute Zn concentration via atomic absorption spectrometry.…”
Section: Introductionmentioning
confidence: 99%
“…148 As aplicações biológicas em LIBS são principalmente de natureza qualitativa, mas também ocorrem análises quantitativas. A aplicação da bio-LIBS estende-se a uma ampla variedade de amostras como, sangue, 158 cabelo, 238 unhas, 239 fígado de pacientes com mal de Wilson, 240 urina, 241 e dentes. 242 O grande potencial da LIBS nesse campo é que não é necessário nenhum conhecimento prévio sobre as sequências de ácido nucléico ou anticorpos contra antígenos bacterianos conhecidos, em contraste com as técnicas de diagnóstico clínico estabelecidas.…”
Section: Biológicas E Farmacêuticasunclassified
“…Good correlation was obtained between the predicted values and reference values. Rusak et al performed the quantitative determination of Ca, Mg, and Zn in 11 fingernails by LIBS using calibration curves, and the best agreement was obtained for the determination of Zn. Sturm et al used LIBS for inline analysis of liquid slag at a steelworks, and the major components such as CaO, Fe, SiO 2 , MgO, Mn, and Al 2 O 3 were compared with reference values from the steelworks' laboratory for solid pressed slag samples as well as for samples from the liquid slag.…”
Section: Quantitative Analysismentioning
confidence: 99%